Samples of accessories, Mounting of 3a approved products – Baumer TE2 User Manual
Page 4
Page 4
Design and specifications subject to change without notice
Installation Manual
www.baumer.com/process
5850-006_EN/2011-10-10
This data sheet ma
y only be reproduced in full.
Samples of Accessories
The FlexProgrammer 9701 is a dedicated tool to configure all
Baumer configurable products.
Type No. 9701-0001 complies:
FlexProgrammer interface unit
CD with the FlexProgram software and product drivers (DTM)
USB cable
Cable with 2 alligator clips
In case the TE1 is equipped with a FlexTop in-head transmitter or the
TE2 is with internal transmiiter the Flexprogrammer will be needed.
A full range of accessories for TE1 and TE2 can be found in the data
sheet ”Accessories”
Mounting of 3A Approved Products
Max. ± 85°
Max. ± 175°
5)
1)
2)
3)
4)
Installation of 3A approved products:
1) Use only a 3A approved counter part.
2) The inspection hole should be visible and drained.
3) Mount the instrument in a self drained position.
4) Level the inner surface of the pipe with the counter part.
5) Weldings should be grinded to Ra= 0.8
Refer to the data sheet “Accessories” for O-rings, gaskets and other
accessories.
The TE1x-7/8/9/A versions are approved by 3A providing it is installed
according to the guidelines given in the installation manual.
The 3A approved products fulfill the FDA demands and follow the
EHEDG guidelines regarding design, materials and finishing.