beautypg.com

Bio-Rad Profinity IMAC Resins User Manual

Page 7

background image

Table 2. Profinity IMAC Resin Specifications

Functional ligand

IDA

Base bead

UNOsphere

Particle size range

45–90 µm

Mean particle size

60 µm

Metal ion capacity

12–30 µmol Cu

2+

/ml

Dynamic binding capacity*

≥15 mg/ml

Recommended linear flow rate

480 cm/hr

Maximum operating pressure

45 psi

Chemical compatibility

See table

Storage

4°C to ambient temperature

Shelf life in 20% EtOH

>1 year at ambient temperature

Operational temperature

4–40°C

*

Q10% determination of 1.8 mg/ml (His)6-tagged pure protein (32 kD).

Note: Dynamic binding capacity will vary from protein to protein.

Profinity IMAC cartridges are compatible with aqueous
buffers most commonly used with IMAC purification
techniques. For a complete list of chemical
compatibilities, refer to the Profinity IMAC
instruction manual, online at http://www.bio-
rad.com/cmc_upload/Literature/164111/10001677
B.PDF.