beautypg.com

Software controlled store/recall cycles [20, 21, Software controlled store/recall cycles – Cypress CY14B256K User Manual

Page 20

background image

CY14B256K

Document Number: 001-06431 Rev. *H

Page 20 of 28

Software Controlled STORE/RECALL Cycles

[20, 21]

Parameter

Alt.

Parameter

Description

25 ns

35 ns

45 ns

Unit

Min

Max

Min

Max

Min

Max

t

RC

t

AVAV

STORE/RECALL Initiation Cycle Time

25

35

45

ns

t

SA

t

AVEL

Address Setup Time

0

0

0

ns

t

CW

t

ELEH

Clock Pulse Width

20

25

30

ns

t

HA

t

EHAX

Address Hold Time

1

1

1

ns

t

RECALL

RECALL Duration

170

170

170

μs

Figure 13. CE Controlled Software STORE/RECALL Cycle

[21]

Figure 14. OE Controlled Software STORE/RECALL Cycle

[21]

t

RC

t

RC

t

SA

t

SCE

t

HA

t

STORE

/ t

RECALL

DATA VALID

DATA VALID

6

#

S

S

E

R

D

D

A

1

#

S

S

E

R

D

D

A

HIGH IMPEDANCE

ADDRESS

CE

OE

DQ (DATA)

t

RC

t

RC

6

#

S

S

E

R

D

D

A

1

#

S

S

E

R

D

D

A

ADDRESS

t

SA

t

SCE

t

HA

t

STORE

/ t

RECALL

DATA VALID

DATA VALID

HIGH IMPEDANCE

CE

OE

DQ (DATA)

Notes

20. The software sequence is clocked with CE controlled or OE controlled READs.
21. The six consecutive addresses are read in the order listed in the

Mode Selection

on page 6. WE is HIGH during all six consecutive cycles.

[+] Feedback