beautypg.com

Additional preset protocols available, Preset protocols application parameters, Plate type # of wells used – Bio-Rad Gene Pulser MXcell™ Electroporation System User Manual

Page 18: Gene pulser mxcell electroporation guide

background image

96-well/Exp

96

96

Use for initial optimal protocol

Applies the same waveform

identification for many cell types

across the whole plate

96-well/Sqr

96

96

Use for initial optimal protocol

Applies the same waveform

identification for many cell types

across the whole plate

Mixed 96-well/Exp, Sqr

96

96

Use for mixing different waveforms

Exp: 20 V, 0 μF

by alternating rows of exponential

Sqr: 20 V, 20 ms

(20 V/0 μF) and square waveforms

(20 V/20 ms)

Mixed 24-well/Exp, Sqr

24

24

Use for mixing different waveforms by

Exp: 20 V, 0 μF, 1,000 Ω

alternating rows of exponential

Sqr: 20 V, 20 ms, 1,000 μF, 1,000 Ω

(20 V/0 μF) and square waveforms

(20 V/20 ms)

24-well/Exp

24

24

Use for initial protocol setup for

Same conditions for the

many cell types

whole plate

24-well/Sqr

24

24

Use for initial protocol setup for

Same conditions for the

many cell types

whole plate

Opt 24-well/Exp, Sqr

24

24

Use with cell line with no protocol

Exp: 10–40 V, 200–1,000 μF

reference; this protocol includes a

Sqr: 10–40 V, –0 ms

range of common starting conditions

Uniform 24-well/Exp, Sqr

24

24

Use with a set of defined conditions

Exp: 20 V, 0 μF, 1,000 Ω

to compare different cell lines and

Sqr: 20 V, 20 ms, 1,000 μF, 1,000 Ω

electroporation of different molecules

within the same or different cell lines

12-well/Exp

12

12

Use for initial protocol setup for many

Same conditions for the

cell types

whole plate

12- well/Sqr

12

12

Use for initial protocol setup for many

Same conditions for the

cell types

whole plate

Opt 12-well/Exp, Sqr

12

12

Use with cell line with no protocol reference; Exp: 10–400 V, 200–00 μF

this protocol includes a range of common

Sqr: 10–00 V, 1–2 ms

starting conditions

Uniform 12-well/Exp, Sqr

12

12

Use with a set of defined conditions to

Exp: 20 V, 0 μF, 1,000 Ω

compare different cell lines and

Sqr: 20 V, 20 ms, 1,000 μF, 1,000 Ω

electroporation of different molecules

within the same or different cell lines

Mixed 12-well/Exp, Sqr

12

12

Use for mixing different waveforms by

Exp: 20 V, 0 μF, 1,000 Ω

alternating rows of exponential

Sqr: 20 V, 20 ms, 1,000 μF, 1,000 Ω

(20 V/0 μF) and square waveforms

(20 V/20 ms)

Additional Preset Protocols Available

Gene Pulser MXcell

Electroporation Guide

Visit us on the Web at discover.bio-rad.com

| Additional Preset Protocols

Preset Protocols

Application

Parameters

See the Gene Pulser MXcell

Electroporation System

manual for more information.

Plate

Type

# of

Wells

Used

1