Operating instructions, Tractor hookup – Great Plains 2025P Operator Manual User Manual
Page 83
8/14/2006
118-928M
81
Veris Drive Operating Instructions
Operating Instructions
Drive Operational Requirements:
Hydraulic System:
• Closed center, pressure compensated or
load sensed systems only
• Drive will not operate on open-centered hy-
draulic systems
Minimum Hyd. Pressure: 2250 psi
Maximum Hyd. Pressure: 3000 psi
Maximum Required Flow:
• 25’
8.5 gpm
Electrical System:
• Voltage:
12 volt DC
• Amperage:
4 amperes
Tractor Hookup
Hydraulics:
1.
Connect pressure hose (P) to retraction outlet
2.
Connect motor return hose (T) to motor return
port (if available) or to extension outlet.
3.
Set flow rate at maximum required flow (8.5
gpm).
4.
If tractor is equipped with electro-hydraulic
valves, set timer to “constant” flow.
Electrical:
Refer to Figure 107
1.
Power must be connected directly to the bat-
tery using power port adapter (PN: 19729).
Make sure the eyelets are properly connected
(Red to positive and Black to negative). Con-
nect female socket to the power port adapter.
Figure 107
22714