Changing Seed Meter Wheel for
20 Series Openers
Choose the correct seed meter wheel for the type
of seed you will be using. Be sure to use the same
wheel type on all meters.
To change seed meter wheels:
Refer to Figure 56
1.
Shut off seed flow to meters by moving sliding
seed tubes. For more information see page
39.
Refer to Figure 57
2.
Clean out meter. For more information see
page 40.
Refer to Figure 58
3.
Push in spring-loaded wheel retainer and
turn. Pull off wheel retainer and spring.