1.2 Electrical

1.2.1 Power Requirements

C-Start requires 120 VAC, 8 Amps service with a dedicated circuit breaker.

Note:

Ensure the protective earth ground wires do not carry any motor return current. Only
the neutral wire should carry return current. Follow local electrical code when wiring
the C-Start.

1.2.2 Conduit Requirements

At a minimum, (3) conduit runs are typically required:

• Power – Conduit run from C-Start to AC Power Service Panel

• Control – Conduit run from C-Start to the Car Wash Controller

• Data – Conduit run to the network router location within the facility. This

conduit may also house Intercom control wires and telephone lines (for dial
credit applications.

Conduit size should be at least ¾ in. Refer to local and national electrical codes to
select the proper conduit type and size. Conduit stubs should be installed to enter the
C-Start base through the oblong conduit opening as shown in Figure 2 and extend at
least 3” above the concrete surface.