Aluminum 30a n, Plasma / h, O shield – Tweco XT-300 Torch Data for Distributor UltraCut-100 AG User Manual
Page 17
Manual 0-4730 Rev. AG
8-17
TORCH DATA
Aluminum
30A
N
2
Plasma / H
2
O Shield
Cartridge
21-1020
Electrode
21-1077
Plasma
Gas Distributor
21-1045
Tip
21-1059
Shield Cap
21-1033
Shield Cup
21-1016
Art # A-04498
Shield
Gas Distributor
21-1274
(ga)
(in)
inch
psi
Ball
psi
Ball
psi*
Volts
(in)
±0.005
(ipm)
(in)
(sec)
(in)
25
0.025
96
55
120
4
55
103
0.030
230
0.080
0.0
0.034
21
0.037
96
55
120
4
55
103
0.030
220
0.080
0.1
0.045
18
0.052
96
55
120
4
55
103
0.030
150
0.080
0.2
0.031
16
0.064
96
55
120
4
55
103
0.030
110
0.080
0.2
0.036
bar
Ball
bar
Ball
bar*
Volts
(mm)
±0.1
(mm/min)
(mm)
(sec)
(mm)
6.6
55
8.3
4
3.8
103
0.8
5310
2.0
0.1
1.1
6.6
55
8.3
4
3.8
103
0.8
1550
2.0
0.2
1.0
* Pressure of the water supply line should be regulated by customer supplied pressure regulator.
Bold type indicates maximum piercing parameters.
(mm)
1
2
Shield (H
2
O)
Initial
Piercing
Height
Shield (H
2
O)
Pierce
Delay
Kerf
Width
@ Rec.
Speed
Cut Flow Rates / Pressures
Plasma (N
2
)
30A Aluminum (N
2
/H
2
O)
Material
Thickness
Pre Flow
Pressure
(N
2
)
Cut Flow Rates / Pressures
Arc
Voltage
Torch
Working
Height
Travel
Speed
Plasma (N
2
)
NOTE 2: Water source used for H
2
O Water Shield must be demineralized.
Initial
Piercing
Height
Pierce
Delay
Kerf
Width
@ Rec.
Speed
NOTE 1: Ohmic height sensing is not recommended with water shield.
Water on the plate interferes electrically with the ohmic sensing circuit.
Arc
Voltage
Torch
Working
Height
Travel
Speed
Material
Thickness
Pre Flow
Pressure
(N
2
)