Tweco 7-5227 User Manual
Page 2
![background image](/manuals/595476/2/background.png)
July 28, 2004
2
Manual 0-4647
C. Current Rating (Refer to Note)
NOTE
Power Supply characteristics will determine ma-
terial thickness range.
SL60 & SL100 Current Ratings
SL60 Torch & Leads
SL100 Torch & Leads
Up to 60 Amps, DC,
Straight Polarity
Up to 100 Amps, DC,
Straight Polarity
D. Torch Ratings
Ambient
Temperature
104° F
40° C
Duty Cycle
100% @ 60 Amps @ 400 scfh
Maximum Current
60 Amps
Voltage (V
peak
)
500V
Arc Striking Voltage
7kV
SL60 Torch Ratings
Ambient
Temperature
104° F
40° C
Duty Cycle
100% @ 100 Amps @ 400 scfh
Maximum Current
100 Amps
Voltage (V
peak
)
500V
Arc Striking Voltage
7kV
SL100 Torch Ratings
E. Type of Cooling
Combination of ambient air and gas stream through torch.
F. Gas Requirements
Gas (Plasma and Secondary)
Compressed Air
Operating Pressure
Refer to NOTE
60 - 75 psi
4.1 - 5.2 bar
Maximum Input Pressure
125 psi / 8.6 bar
Gas Flow (Cutting and Gouging)
300 - 500 scfh
(142 - 235 lpm)
SL60 and SL100 Torch Gas Specifications
WARNING
This torch is not to be used with oxygen (O
2
).
NOTE
Operating pressure varies with torch model and
operating amperage. Refer to gas pressure settings
chart for each model.
G. Direct Contact Hazard
For exposed tip the recommended standoff is 1/8" - 1/4" (3 - 6.4
mm).
H. Parts-In-Place (PIP) Circuit - 12 vdc
The torch and leads include circuitry called Parts-In-Place
(PIP). This circuit includes a switch located at the torch
head. The shield cup closes this switch when properly
installed. The torch will not operate if this switch is open.
A-02997
Torch Trigger
PIP Switch
Shield Cup
To Control
Cable Wiring
Torch Switch