beautypg.com

Thermal arc 161 s installation, 07 lift tig (gtaw) setup – Tweco 161 S UK User Manual

Page 22

background image

THERMAL ARC 161 S

INSTALLATION

Installation 3-6

3-6

Manual 0-5183

3.07 LIFT TIG (GTAW) Setup

Figure 3-3: Setup for LIFT TIG (GTAW) Welding

Set Process Selection

Switch to LIFT TIG (GTAW).

Positive Output

Terminal

(Dinse™ 50)

Negative

Output

Terminal

(Dinse™ 50)

Art #: A-09915

Set Welding Current

as specified by the

Electrode Manufacturer.

Secure the gas cylinder in an

upright position by chaining it

to a stationary support to prevent

falling or tipping.

LIFT TIG (GTAW) Sequence of Operation

CAUTION

Before any welding is to begin, be sure to wear all

appropriate and recommended safety equipment.

1. Switch the ON/OFF Switch (located on the rear panel)

to OFF.

2. Connect the ground clamp cable to positive output

terminal, and the TIG torch cable to the negative

output terminal.

NOTE

This set up is known as Straight Polarity or DC

Electrode Negative. This is commonly used for DC

TIG welding on most materials such as steel and

stainless steel.

3. Using a secured Argon cylinder, slowly crack open

then close the cylinder valve while standing off to

the side of the valve. This will remove any debris that

may be around the valve & regulator seat area.

4. Install the regulator as per the manufacturers

instructions.

5. Connect the gas hose to the outlet of the Argon

regulator, and tighten with a spanner.

6. Be sure the gas valve on the torch is closed, and

slowly open the Argon Cylinder Valve to the fully

open position.

7. Connect the ground clamp to your workpiece.
8. Plug the power cable into the appropriate outlet,

and turn the switch to the “ON” position. The power

L.E.D. light should illuminate.