INSTALLATION

Installation 3-2

3-2

Manual 0-5183

• Electrical Input Requirements
Operate the welding power source from a single-phase 50/60 Hz, AC power supply. The input voltage must match

one of the electrical input voltages shown on the input data label on the unit nameplate. Contact the local electric

utility for information about the type of electrical service available, how proper connections should be made, and

inspection required. The line disconnect switch provides a safe and convenient means to completely remove all

electrical power from the welding power supply whenever necessary to inspect or service the unit.
Do not connect an input ((BROWN or BLUE)) conductor to the ground terminal.
Do not connect the ground ((GREEN or GREEN/YELLOW)) conductor to an input line terminal.
1. Connect end of ground (GREEN or GREEN/YELLOW) conductor to a suitable ground. Use a grounding method

that complies with all applicable local electrical codes.

2. Connect ends of line Active (BROWN) and Neutral (BLUE) input conductors to a suitable power supply system

that complies with all applicable local electrical codes.

3. Use Table 3-1 as a guide to select line fuses for the disconnect switch.

Input Voltage

Circuit Breaker or Fuse Size

110V

32A

230V

32A

Table 3-1: Fuse Guide

CAUTION

The time-delay fuses or circuit breaker of an individual branch circuit may have nuisance tripping when

welding with this product due to the amperage rating of the time-delay fuses or circuit breaker.

Input Power
Each unit incorporates an INRUSH circuit. When the MAIN CIRCUIT SWITCH is turned on, the inrush circuit

provides pre-charging for the input capacitors. A relay in the Power Control Assembly (PCA) will turn on after the

input capacitors have charged to operating voltage (after approximately 5 seconds)

NOTE

Damage to the PCA could occur if 253 VAC or higher is applied to the Primary Power Cable.

Model

Primary Supply Lead

Size (Factory Fitted)

Minimum Primary

Current Circuit Size

(Vin/Amps)

Current & Duty Cycle

LIFT TIG (GTAW)

STICK (MMA)

Thermal Arc

161 S

H07RN-F 3x1.5mm²

110V/35.5A

-

125A @ 20%

110V/21.3A

125A @ 50%

-

230V/23.2A

-

160A @ 35%

230V/14.4A

160A @ 40%

-

Table 3-2: Primary Circuit Sizes to Achieve Maximum Current