Cutmaster 40mm – Tweco 40mm Cutmaster User Manual
Page 61

CUTMASTER 40mm
Manual 0-5084
5-7
SERVICE
5. Remove the fitting from the filter element
assembly by inserting a 6 mm hex wrench
into the internal hex fitting and turning it
counter clock-wise (left). Numbers 4 and 5
in the previous illustration.
6. Disconnect the input line from the filter
element assembly.
7. Remove the filter element assembly
through the rear opening.
NOTE
If replacing or cleaning just the filter element
refer to the following illustration for disassembly.
Art # A-07990
Filter Element
8. Install the new or cleaned assembly by
reversing these procedures.
9. Turn ON the air supply and check for leaks
before reinstalling the cover.
Optional Single-Stage Filter Element
Replacement
These instructions apply to power supplies where
the optional Single-Stage Filter has been installed.
The Power Supply shuts down automatically
when the Filter Element becomes completely sat-
urated. The Filter Element can be removed from
its housing, dried, and reused. Allow 24 hours for
Element to dry. Refer to Section 6, Parts List, for
replacement filter element catalog number.
1. Remove power from power supply.
2. Shut OFF air supply and bleed down sys-
tem before disassembling Filter to change
Filter Element.
3. Disconnect gas supply hose.
4. Turn the Filter Housing Cover counter-
clockwise and remove it. The Filter Ele-
ment is located inside the Housing.
Art # A-02476
Filter
Element
(Cat. No. 9-7741)
Housing
Cover
Barbed
Fitting
Spring
Assembled Filter
O-ring
(Cat. No. 9-7743)
Optional Single-Stage Filter Element Replacement
5. Remove the Filter Element from the Hous-
ing and set Element aside to dry.
6. Wipe inside of housing clean, then insert
the replacement Filter Element open side
first.
7. Replace Housing on Cover.
8. Reattach gas supply.
NOTE
If unit leaks between housing and cover, inspect
the O-Ring for cuts or other damage.