Cutmaster 40mm – Tweco 40mm Cutmaster User Manual
Page 46

CUTMASTER 40mm
OPERATION 4T-14
Manual 0-5084
Type Torch: SL100 With Exposed Tip
Type Material: Mild Steel
Type Plasma Gas: Air
Type Secondary Gas: Single Gas Torch
Thickness
Tip
Output
Amperage Speed (Per Minute)
Standoff
Plasma Gas Press
Flow (CFH)
Pierce
Pierce Height
Inches mm (Cat. No.) Volts(VDC) (Amps)
Inches
Meters
Inches mm
psi*
bar
Plasma Total** Delay (Sec) Inches mm
0.250 6.4
9-8253
138
120
150
3.81
0.19
4.8
75
5.2
180
360
0.10
0.25
6.4
0.375 9.5
9-8253
140
120
85
2.16
0.19
4.8
75
5.2
180
360
0.30
0.25
6.4
0.500 12.7 9-8253
144
120
70
1.78
0.19
4.8
75
5.2
180
360
0.50
0.25
6.4
0.625 15.9 9-8253
152
120
45
1.14
0.19
4.8
75
5.2
180
360
0.70
0.25
6.4
0.750 19.0 9-8253
155
120
30
0.76
0.19
4.8
75
5.2
180
360
0.90
0.25
6.4
0.875 22.2 9-8253
160
120
25
0.64
0.25
6.4
75
5.2
180
360
NR
NR
NR
1.000 25.4 9-8253
164
120
20
0.51
0.25
6.4
75
5.2
180
360
NR
NR
NR
1.250 31.8 9-8253
170
120
12
0.30
0.25
6.4
75
5.2
180
360
NR
NR
NR
1.500 38.1 9-8253
180
120
8
0.20
0.25
6.4
75
5.2
180
360
NR
NR
NR
Type Torch: SL100 With Exposed Tip
Type Material: Stainless Steel
Type Plasma Gas: Air
Type Secondary Gas: Single Gas Torch
Thickness
Tip
Output
Amperage Speed (Per Minute)
Standoff
Plasma Gas Press
Flow (CFH)
Pierce
Pierce Height
Inches mm (Cat. No.) Volts(VDC)
(Amps)
Inches
Meters
Inches mm
psi*
bar
Plasma Total** Delay (Sec) Inches mm
0.250 6.4 9-8253
135
120
180
4.57
0.19 4.8
75
5.2
180
360
0.20
0.25
6.4
0.375 9.5 9-8253
144
120
100
2.54
0.19 4.8
75
5.2
180
360
0.40
0.25
6.4
0.500 12.7 9-8253
146
120
60
1.52
0.19 4.8
75
5.2
180
360
0.80
0.25
6.4
0.625 15.9 9-8253
155
120
40
1.02
0.25 6.4
75
5.2
180
360
1.20
0.28
7.0
0.750 19.0 9-8253
164
120
26
0.66
0.25 6.4
75
5.2
180
360
NR
NR
NR
1.000 25.4 9-8253
164
120
18
0.46
0.25 6.4
75
5.2
180
360
NR
NR
NR
1.250 31.8 9-8253
170
120
9
0.23
0.25 6.4
75
5.2
180
360
NR
NR
NR
Type Torch: SL100 with Exposed Tip
Type Material: Aluminum
Type Plasma Gas: Air
Type Secondary Gas: Single Gas Torch
Thickness
Tip
Output
Amperage Speed (Per Minute)
Standoff
Plasma Gas Press
Flow (CFH)
Pierce
Pierce Height
Inches mm (Cat. No.) Volts(VDC) (Amps)
Inches
Meters
Inches mm
psi*
bar
Plasma Total** Delay (Sec) Inches mm
0.250 6.4 9-8253
142
120
190
4.83
0.19
4.8
75
5.2
180
360
0.30
0.25
6.4
0.375 9.5 9-8253
145
120
120
3.05
0.19
4.8
75
5.2
180
360
0.50
0.25
6.4
0.500 12.7 9-8253
151
120
70
1.78
0.19
4.8
75
5.2
180
360
0.80
0.25
6.4
0.625 15.9 9-8253
162
120
50
1.27
0.25
6.4
75
5.2
180
360
1.00
0.28
7.0
0.750 19.0 9-8253
164
120
34
0.86
0.25
6.4
75
5.2
180
360
NR
NR
NR
1.000 25.4 9-8253
170
120
20
0.51
0.25
6.4
75
5.2
180
360
NR
NR
NR
NOTES
* Gas pressure shown is for torches with leads up to 25’ / 7.6 m long. For 50’ / 15.2 m leads, refer to section
4.02 "Operating Pressure".
** Total flow rate includes plasma and secondary gas flow.