Cutmaster 152 – Tweco 152 CutMaster User Manual
Page 44
CUTMASTER 152
OPERATION
Manual 0-4987
4T-12
Type Torch: SL100 with Exposed Tip
Type Material: Aluminum
Type Plasma Gas: Air
Type Secondary Gas: Single Gas Torch
Thickness
Tip
Output
Amperage Speed (Per Minute)
Standoff
Plasma Gas Press
Flow (CFH)
Pierce
Pierce Height
Inches mm (Cat. No.) Volts(VDC) (Amps)
Inches
Meters
Inches mm
psi*
bar
Plasma Total** Delay (Sec) Inches mm
0.06
1.5 9-8211
120
80
350
8.89
0.25
6.4
65
4.5
115
340
0.00
0.25
6.4
0.12
3.0 9-8211
124
80
300
7.62
0.25
6.4
65
4.5
115
340
0.10
0.25
6.4
0.188 4.8 9-8211
124
80
180
4.57
0.25
6.4
65
4.5
115
340
0.20
0.25
6.4
0.250 6.4 9-8211
128
80
110
2.79
0.25
6.4
65
4.5
115
340
0.30
0.25
6.4
0.375 9.5 9-8211
136
80
55
1.40
0.25
6.4
65
4.5
115
340
0.40
0.25
6.4
0.500 12.7 9-8211
139
80
38
0.97
0.25
6.4
65
4.5
115
340
0.60
0.25
6.4
0.625 15.9 9-8211
142
80
26
0.66
0.25
6.4
65
4.5
115
340
0.75
0.25
6.4
0.750 19.1 9-8211
145
80
24
0.61
0.25
6.4
65
4.5
115
340
NR
NR
NR
0.875 22.2 9-8211
153
80
10
0.25
0.25
6.4
65
4.5
115
340
NR
NR
NR
1.000 25.4 9-8211
162
80
6
0.15
0.25
6.4
65
4.5
115
340
NR
NR
NR
Type Torch: SL100 With Exposed Tip
Type Material: Mild Steel
Type Plasma Gas: Air
Type Secondary Gas: Single Gas Torch
Thickness
Tip
Output
Amperage Speed (Per Minute)
Standoff
Plasma Gas Press
Flow (CFH)
Pierce
Pierce Height
Inches mm (Cat. No.) Volts(VDC) (Amps)
Inches
Meters
Inches mm
psi*
bar
Plasma Total** Delay (Sec) Inches mm
0.250
6.4 9-8212
110
100
105
2.65
0.190 4.8
75
5.2
130
390
0.4
0.200 5.1
0.375
9.5 9-8212
117
100
70
1.75
0.190 4.8
75
5.2
130
390
0.5
0.200 5.1
0.500
12.7 9-8212
120
100
50
1.25
0.190 4.8
75
5.2
130
390
0.6
0.200 5.1
0.625
15.9 9-8212
125
100
35
0.90
0.190 4.8
75
5.2
130
390
1.0
0.200 5.1
0.750
19.0 9-8212
131
100
18
0.45
0.190 4.8
75
5.2
130
390
2.0
0.250 6.4
1.000
25.4 9-8212
135
100
10
0.25
0.190 4.8
75
5.2
130
390
NR
NR
NR
Type Torch: SL100 With Exposed Tip
Type Material: Stainless Steel
Type Plasma Gas: Air
Type Secondary Gas: Single Gas Torch
Thickness
Tip
Output
Amperage Speed (Per Minute)
Standoff
Plasma Gas Press
Flow (CFH)
Pierce
Pierce Height
Inches mm (Cat. No.) Volts(VDC)
(Amps)
Inches
Meters
Inches mm
psi*
bar
Plasma Total** Delay (Sec) Inches mm
0.250 6.4 9-8212
118
100
90
2.30
0.190 4.8
75
5.2
130
390
0.5
0.250 6.4
0.375 9.5 9-8212
122
100
55
1.40
0.190 4.8
75
5.2
130
390
0.8
0.250 6.4
0.500 12.7 9-8212
126
100
30
0.75
0.190 4.8
75
5.2
130
390
1.0
0.250 6.4
0.625 15.9 9-8212
133
100
20
0.50
0.190 4.8
75
5.2
130
390
1.5
0.250 6.4
0.750 19.0 9-8212
138
100
15
0.40
0.190 4.8
75
5.2
130
390
NR
NR
NR
1.000 25.4 9-8212
139
100
10
0.25
0.190 4.8
75
5.2
130
390
NR
NR
NR
Type Torch: SL100 with Exposed Tip
Type Material: Aluminum
Type Plasma Gas: Air
Type Secondary Gas: Single Gas Torch
Thickness
Tip
Output
Amperage Speed (Per Minute)
Standoff
Plasma Gas Press
Flow (CFH)
Pierce
Pierce Height
Inches mm (Cat. No.) Volts(VDC) (Amps)
Inches
Meters
Inches mm
psi*
bar
Plasma Total** Delay (Sec) Inches mm
0.250 6.4 9-8212
108
100
120
3.05
0.190 4.8
65
4.5
120
360
0.2
0.225 5.7
0.375 9.5 9-8212
117
100
65
1.65
0.190 4.8
65
4.5
120
360
0.4
0.225 5.7
0.500 12.7 9-8212
120
100
45
1.15
0.190 4.8
65
4.5
120
360
0.5
0.225 5.7
0.625 15.9 9-8212
125
100
30
0.75
0.190 4.8
65
4.5
120
360
0.8
0.225 5.7
0.750 19.0 9-8212
131
100
25
0.65
0.190 4.8
65
4.5
120
360
1.0
0.225 5.7
1.000 25.4 9-8212
140
100
10
0.25
0.190 4.8
65
4.5
120
360
NR
NR
NR