Manual 0-5284
CCM Status Code
Group 6 -- CCM
Code
Message
Remedy / Comments
601
Analog Voltage Error
Defective CCM, replace.
602
ADC or DAC error
Defective CCM, replace.
603
Reserved
No information available; Contact customer service
604
Data Memory error
Defective CCM, replace.
605
Program memory fault Defective CCM, replace.
606
+5V Logic supply low Defective CCM, replace.
607
Processor over tem-
perature
Reduce ambient temperature; Defective CCM; replace
608
5V supply for RS
485/422 communica-
tion low.
Defective CCM, replace.
609
Firmware Update
Device Error
Defective CCM; replace
610
Firmware Update
Protocol Error
Defective CCM; replace
611
USB Controller Fault
Defective CCM; replace
612
USB Power Fault
Remove faulty USB device; Defective CCM
613
USB Log Creation Fault Unable to create Log file on USB Flash drive last firmware update attempt; Use different USB
Flash Drive or Reformat
614
No USF File
File VTCCMFW.USF missing from Flash Drive; Add proper files to Flash Drive for Firmware
Update; Use different USB Flash Drive or Reformat
615
No CCM Update File
CCM Firmware file specified in VTCCMFW.USF not found ; Add proper files to Flash Drive for
Firmware updating
616
DPC Update Fault
Fault occurred attempting to update DPC firmware; Add proper files to USB Flash drive for
Firmware updating; Refer to CCM_LOG.TXT on Flash Drive for details
617
DMC Update Fault
Fault occurred attempting to update DMC firmware; Add proper files to USB Flash drive for
Firmware updating; Refer to CCM_LOG.TXT on Flash Drive for details
618
ADC Calibration Fault
Error too large calibrating ADC; Fault persists defective CCM;
619
Flow Switch Fault
Flow switch reporting coolant flow when pump off;
620
Non Volatile Memory
Error
Non Volatile Memory Storage Corrupted and Erased; Fault persists defective CCM.