05 primary power connections, Primary power connections -4, Auto-cut 200 xt – Tweco 200 XT Auto-Cut 400V User Manual
Page 28: Connect input power and system ground cables, Input power

AUTO-CUT 200 XT
3-4
INSTALLATION
Manual 0-5284
3.05 Primary Power Connections
The primary power cable and through hole cable grip must be supplied by the end user and connected to the power
supply. Refer to local and national electrical codes for suggested cable and fuse sizes.
Connect Input Power and System Ground Cables
1. Remove the input power cover to the right of the coolant filter at the rear of the power supply. To do this
remove the two screws then lift up and pull away.
2. Carefully cut back the outer sheath on the primary input power cable to expose the individual wires. Cut
back the insulation on the individual wires. Route the cable upward through Input Power Port at the bottom
of the panel. There are 2 extra plates included at the cable entrance. Discarding one or both allows changing
the opening size for larger cable/strain relief.
J15 - CNC
CB4 - 5A 120 VAC
F1 - 8A SB 230 VAC
F2 - 8A SB 230 VAC
CB3 - 5A 24 VAC
CB2 - 5A 120 VAC
USER INPUT
HEIGHT CONTROL
AIR / O2
PLASMA
N2 / H35
PLASMA
Input Power
Art # A-11949