SERVICE 5-2 Manual 0-5180
A. Every three months
Check	external	air	filter,	replace	if	necessary.
1.	 Shut	off	input	power;	turn	off	the	gas	supply.	
Bleed down the gas supply. Check air filter and replace if neces-
sary.
NOTE
Leave internal ground wire in place.
B. Every six months
1.	 Check	the	in-line	air	filter(s),	clean	or	replace	as	required.
2.	 Check	cables	and	hoses	for	leaks	or	cracks,	replace	if	necessary.
3.	 Check	all	contactor	points	for	severe	arcing	or	pits,	replace	if	necessary.
4.	 Vacuum	dust	and	dirt	out	of	the	entire	machine.
5.02 Basic Troubleshooting Guide
!
WARNING
There are extremely dangerous voltage and power levels present inside this unit. Do not attempt to diagnose
or repair it unless you are an accredited service provider and you have had training in power electronics
measurement and troubleshooting techniques.
1. Common Faults symptom
A. Gas regulator leakage
1)
Gas regulator on
a.
Reset the regulator to 0 PSI and re-adjust it to 75 PSI (5.2 bar).
B. AC indicator
OFF
1)
Main input power cord does not connect to power distribution net.
a.
Connect the power cord.
2)
Power ON/OFF switch in OFF (down) position.
a.
Turn switch to ON (up) position.
3)
Actual input voltage does not correspond to voltage of unit.
a.
Verify that the input line voltage is correct.
4)
Faulty components in unit
a.
Return for repair or have qualified technician repair per service manual.
C. Torch will not pilot; When trigger is activated, Air indicator ON.
1)
Gas pressure too low. Adjust the pressure to 75 PSI/5.2 bar.
D. AC indicator ON, TEMP indicator ON.
1)
Air flow blocked
a.
Check for blocked air flow around the unit and correct condition.
2)
Fan blocked
a.
Check for blocked status and correct condition.