02 preparations for operating, Cutskill 35a – Tweco 35A CutSkill Power Supply and SL40 Torch EU version User Manual
Page 22

cutskill 35A
OPERATION 4-2 Manual 0-5180
8. Parts - in - place ( PIP)
This unit is fitted with a protective interlock mode (parts in place sensor), which serves to protect the user from
potentially dangerous voltages when changing consumables. If the shield cup is not correctly fitted, the output
will be disabled and the air indicator will flash.
NOTE
All consumables must be correctly fitted and maintained to ensure correct operation.
4.02 Preparations For Operating
At the start of each operating session:
!
WARNING
Disconnect primary power at the source before assembling or disassembling power supply, torch parts,
or torch and leads assemblies.
A. Torch Parts Selection
Check the torch for proper assembly and appropriate torch parts. The torch parts must correspond with the type
of operation, and with the amperage output of this power supply (35 amps maximum). Use only genuine Thermal
Dynamics parts with this torch.
Art # A-09793_AC
Start Cartridge,
Cat. No. 9-0097
Electrode, Cat. No. 9-0096
Shield Cup, Cat. No. 9-8218
Worn Electrode
Worn Tip
35 Amp Drag Tip, Cat. No. 9-0091
Shield Cup, Cat. No. 9-0098