beautypg.com

Cutmaster a120 – Tweco A120 CutMaster User Manual

Page 33

background image

CUTMASTER A120

Manual 0-4989

OPERATION

4-3

STANDOFF

CutMaster A120 Gas Pressure Settings

Leads

Length

SL100

(Hand Torch)

SL100

(Mechanized Torch)

SL100 SV

(Automation Torch)

Up to 50'

(7.6 m)

75 psi

5.2 bar

75 psi

5.2 bar

Each additional

25' (7.6 m)

Add 5 psi

0.4 bar

Add 5 psi

0.4 bar

3. For Drag cutting (60 Amps and below), adjust gas pres-

sure from 75 - 95 psi / 5.2 - 6.5 bar (LED's in center

of control panel). Refer to the Drag Cutting chart for

pressure setting details.

DRAG (60 Amps or less)

CutMaster A120 Gas Pressure Settings

Leads

Length

SL100

(Hand Torch)

Up to 25'

(7.6 m)

80 psi

5.5 bar

Each additional

25' (7.6 m)

Add 5 psi

0.4 bar

Select Current Output Level

1. Place the Function Control Knob in one of the three

operating positions available:

RUN

,

RAPID AUTO RESTART

or LATCH

. Gas flow stops.

2. Set the output current to desired amperage with the

Output Current Control Knob.

Pre-flow

With hand or mechanical torch, there will be a .5 second

pre-flow of the gas. Pre-flow does not apply to automa-

tion torch use.

Cutting Operation

When the torch leaves the workpiece during cutting opera-

tions with the Function Control Knob in the RUN position,

there is a brief delay in restarting the pilot arc. With the

knob in the

RAPID AUTO RESTART position, when

the torch leaves the workpiece the pilot arc restarts in-

stantly, and the cutting arc restarts instantly when the pilot

arc contacts the workpiece. (Use the 'Rapid Auto Restart'

position when cutting expanded metal or gratings, or in

gouging or trimming operations when an uninterrupted

restart is desired). And with the knob in the LATCH posi-

tion the main cutting arc will be maintained after the torch

switch is released.

Typical Cutting Speeds

Cutting speeds vary according to torch output amperage,

the type of material being cut, and operator skill. Refer to

Section 4T.08 and following for greater details.

Output current setting or cutting speeds may be reduced

to allow slower cutting when following a line, or using

a template or cutting guide while still producing cuts of

excellent quality.

Postflow

Release the trigger to stop the cutting arc. Gas continues

to flow for approximately 20 seconds. During post - flow, if

the user moves the trigger release to the rear and presses

the trigger, the pilot arc starts. The main arc transfers to

the workpiece if the torch tip is within transfer distance to

the workpiece.

Shutdown

Turn the ON / OFF

switch to OFF

(down). All

Power Supply indicators shut OFF. Unplug the input power

cord or disconnect input power. Power is removed from

the system.