beautypg.com

Cutmaster a120, 04 fault indicator – Tweco A120 CutMaster User Manual

Page 109

background image

CUTMASTER A120

Manual 0-4989

SERVICE

5-3

5.04 Fault Indicator

At initial power up, two lights will temporarily illuminate for 2-3

seconds to show the version of software used.

To determine the first digit, count the function indicators left

to right, 1 through 5. To determine the second digit count the

pressure indicators, reading from bottom to top, 0 through 7.

In the example below the Temp indicator and 76 psi indicators

are ON indicating the version would be 2.3.

A

+

PSI

BAR

MAX

MAX

MIN

MIN

!

1 2 3 4

Art# A-07988

MIN

MAX

0

1

2

3

4

5

6

7

5

When the

!

"Fault" indicator is ON or blinking it will be

accompanied by one of the pressure indicator lights de-

pending on what the Fault is. The following table explains

each of those Faults.

Pressure

Indicator

Fault

Max

Over Pressure

90

Internal Error

85

Shorted Torch

80

Consumables Missing

75

Start Error

70

Parts in Place

65

Input Power

Min

Under Pressure

NOTE

Fault explanations are covered in the following

tables.