beautypg.com

Cutmaster 10mm, 12mm, 2t.01 scope of operating manual, 2t.02 specifi cations – Tweco CutMaster 10mm-12mm User Manual

Page 19

background image

CUTMASTER 10MM, 12MM

Manual 0-5197AC 2T-1 TORCH INTRODUCTION

2T.01 Scope of Operating Manual

This manual contains descriptions, operating instructions
and maintenance procedures for the SL60 Plasma Cutting
Torch. Service of this equipment is restricted to properly
trained personnel; unqualified personnel are strictly
cautioned against attempting repairs or adjustments not
covered in this manual, at the risk of voiding the Warranty.
Read this manual thoroughly. A complete understanding
of the characteristics and capabilities of this equipment
will assure the dependable operation for which it was
designed.

2T.02 Specifi cations

A. Torch Confi gurations

1. Hand Torch, Model SL60

The hand torch head is at 75° to the torch handle.
The hand torch includes a torch handle and torch
trigger assembly.

10.125" (257 mm)

3.75"

(95 mm)

1.17" (29 mm)

Art # A-03322_AB

Figure 2T-1 - SL60 Torch

B. Torch Leads Lengths

Hand Torches are available as follows:

• 20 ft / 6,2m

C. Torch

Parts

Starter Cartridge, Electrode, Tip, Shield Cup
(See "Figure 4-3 - SL60 Torch Parts" on page 4-2.)

D. Parts-In-Place (PIP)

Torch has built-in switch.

12 VDC circuit rating.

E. Type

Cooling

Combination of ambient air and gas stream through
torch.

F. Torch

Ratings

SL60 Torch Ratings

Ambient

Temperature

104° F

40° C

Duty Cycle

100% @ 60 Amps @ 400 scfh

Maximum Current

60 Amps

Voltage (V

peak

)

500V

Arc Striking Voltage

7kV

scfh =

Standard cubic foot per hour

G. Current Ratings

SL60 Current Ratings

SL60 Torch & Leads

Up to 60 Amps, DC,

Straight Polarity

NOTE

Power Source characteristics will determine
material thickness range.

H. Gas Requirements

SL60 Torch Gas Specifi cations

Gas (Plasma and Secondary)

Compressed Air

Operating Pressure

Refer to NOTE

60 - 75 psi

4.1 - 5.2 bar

Maximum Input Pressure

125 psi / 8.6 bar

Gas Flow

300-500 scfh

142-235 lpm

lpm =

Litre per minute

!

WARNING

This torch is NOT TO BE used with oxygen (O

2

).

NOTE

Operating pressure varies with torch model,
operating amperage, and torch leads length.
Refer to gas pressure settings charts for each
model.

SECTION 2 TORCH:

INTRODUCTION