beautypg.com

Tweco 6000 Cutting System User Manual

Page 20

background image

INSTALLATION PROCEDURES

16

Manual 0-2572

5. Connect the power lead to the buss bar per the

following procedure:

a. Remove the nut and washer from the upper

bolt.

b. Remove the bolt and washer from the upper

hole of the buss bar.

c. Place the ring lug on the power lead over the

end of the bolt.

d. Re-install the bolt and washer with the lug

into the upper hole of the buss bar.

e. Re-install the nut and washer to secure the

lead.

A-01977

Buss Bar

Washer

Bolt

Power Lead

Nut

Washer

Figure 3-15 Power Lead Connection - Slave

6. Connect the other end of the Pilot Lead, two wires,

to the Slave Power Supply per the following pro-
cedure:

a. Remove the right side panel from the Slave

Power Supply.

b. Feed the Pilot Lead, two wires, through the

small strain relief at the front panel of the Slave
Power Supply.

c. Remove the nut and star washer on the ground

terminal of the pilot connection inside the
power supply.

d. Secure the shield lead (black) to the ground

connection with the nut and star washer re-
moved above.

e. Remove the nut and star washer from the other

pilot connection inside the power supply.

f. Secure the pilot lead (red) to the pilot connec-

tion with the nut and star washer removed
above.

Small Strain

Relief

Black Wire

of Pilot Lead

Ground Terminal

Nut

Star Washer

Pilot Terminal

Red Wire

of Pilot Lead

A-01536

Figure 3-16 Pilot Lead Connection at Slave Power

Supply

9. Connect the other end of the Power Lead to the

Slave Power Supply per the following procedure:

a. Feed the Power Lead through the large strain

relief at the front panel of the Slave Power Sup-
ply.

b. Remove the nut from the power connection

terminal inside the power supply.

c. Secure the power lead to the connection with

the nut removed above.

Large

Strain Relief

Power Lead

Nut

Power Lead

Terminal Bolt

A-01496

Figure 3-17 Power Lead Connection at Slave Power

Supply