Page 7: 2 standard system configurations

REV6 OPERATION / MAINTENANCE MANUAL
7
CONTENTS
Seal Type
PN
Part Description
Plant Connection
O12T12
GROUP;ADPTR;3/4IN TUBE;FFKM O-RING
3/4” tube stub
O12X12
GROUP;ADPTR;3/4IN PILLAR;FFKM O-RING
3/4” Pillar Super 300
If additional fluid connections are needed, contact your Trebor representative for options
All flare nuts are constructed of PVDF. PFA nuts are available on request.
PrimeLock and Pillar Super 300 are trademarks of Entegris, Inc. and Nippon Pillar Packing Co. LTD,
respectively.
Additional components are available for the Rev6. Extension cables to pair the controller to the pump
are available at several different lengths. A sensor cable and power cable are needed for each
motor/controller pair. A 48V power supply is also needed for the motor and controller. The specific
accessories and part numbers are listed below. See 2.2 below for descriptions and diagrams of
different pump setups.
Table 4
– Additional Accessories
Accessory
PN
Description
Comments
Power
Cable
98004272-01 CABLE;POWER;0.5m;REV6
PVC Jacket
Circular AMP and D-Sub Plastic
Connectors
98004272-02 CABLE;POWER;3m;REV6
98004272-03 CABLE;POWER;5m;REV6
98004272-04 CABLE;POWER;7m;REV6
98004272-05 CABLE;POWER;10m;REV6
Sensor
Cable
98004273-01 CABLE;SENSORS;0.5m;REV6
PVC Jacket
Circular AMP and D-Sub Plastic
Connectors
98004273-02 CABLE;SENSORS;3m;REV6
98004273-03 CABLE;SENSORS;5m;REV6
98004273-04 CABLE;SENSORS;7m;REV6
98004273-05 CABLE;SENSORS;10m;REV6
Power
Supply
98004274
POWER SUPPLY;48V;REV6
TSP-600-148-M
(M=Modified design from Traco)
Output: 48 VDC, 600 W
Input: 85-265 VAC (auto detect)
CE, CB, UL, CSA, SEMI F47
Air Cooling
Module
98004282
MODULE;AIR COOLING;REV6
PP (+40% Talc)
NPT 1/4” Connection
1-3 bar (14-43 psi)
– 100 LPM @ 1 bar
2.2 Standard System Configurations
2.2.1 Pump Only Configuration
The Rev6 pump can be purchased without a motor or controller to replace a pump in an existing
installation. The Rev6 is a drop-in replacement for the Levitronix BPS-600. This configuration comes
with the assembled pump and four 316 stainless steel screws to attach the pump to the motor.
2.2.2 Stand-Alone System Configuration
The stand-alone pump system configuration (Figure 2) consists of a controller with an integrated user
panel to set the speed manually. The speed is adjusted using the buttons on the control panel and
automatically stored in the internal EEPROM of the controller. As an alternative, the pump speed can
also be set with an external analog signal.