4.2 Mechanical Installation of the Pump/Motor

The motor can be fixed with four screws on the motor feet (see Figure 6)

As an alternative the motor can be mounted with four screws on the back (see Figure 7)

The motor can be mounted in either the horizontal or the vertical position

Each motor is identified with a unique serial number. This serial number consists of a series of 6

digits where the 5

th

and the 6

th

digit represent the manufacturing year.

4.3 Mechanical Installation of the Controller

WARNING

Hazardous voltage may be present.

In order to avoiding fluid spills shorting mains or other voltages within the
controller, place the controller in a spill-protected environment (for example
protected electronic cabinets).

If explosive flammable gases are present, place the controller in an explosion-
proof cabinet.

CAUTION

Make sure the controller is mounted in a position that allows free air circulation
around the controller. A minimum distance of 10cm (4”) to other objects above or
below the controller casing is recommended.

Use the Din-Rail bracket to mount the controller.

If no forced air-cooling is used, mount the controller in upright position.

The Din-Rail brackets can also be mounted on the controller side according to Figure 9

CAUTION

Use only 3.5 x 6.5mm self-tapping screw for the fixation of the Din-Rail brackets.
The controller may be damaged if other screws are used!

4.4 Mechanical Installation of Adapter/Extension Cables

For connecting the motor to the controller, use adaptor cables 98004272-## (for power cable) and
98004273-## (for sensor cable) (see Table 4 for details).