REV6 OPERATION / MAINTENANCE MANUAL
24
CONTENTS
Table 8
– Description of “USER INTERFACE” Connector
Pin
Pin
Number
Function
Name
Levels
Note
Signal
5
Analog In
Reference
Speed
4-20 mA = 0-10000 rpm
Upper Speed Limit = 9000 rpm
≈ 18.4 mA
Lower Speed Limit = 300 rpm
Direct connection, no protection.
Galvanic isolation on the user side is
required.
Ground
6
Signal
3
Digital In
Enable
24 V → active
0 V → not active
Needed to enable the system with an
external signal.
Ground
4
Signal
1
Digital
Out
Status
Relay
closed → active, system
on
Relay open → not active,
system off
This signal indicates if the system is
active.
Ground
2
Figure 21
– “USER INTERFACE” Connector
-
Delivered with Controller
-
Connector Type: AK1550/06-3.81-Green
Figure 22
– “USER INTERFACE” Pin Numbering