beautypg.com

Trebor REV6 User Manual

Page 24

background image

REV6 OPERATION / MAINTENANCE MANUAL

24

CONTENTS

Table 8

– Description of “USER INTERFACE” Connector

Pin

Pin

Number

Function

Name

Levels

Note

Signal

5

Analog In

Reference

Speed

4-20 mA = 0-10000 rpm
Upper Speed Limit = 9000 rpm

≈ 18.4 mA

Lower Speed Limit = 300 rpm

Direct connection, no protection.
Galvanic isolation on the user side is

required.

Ground

6

Signal

3

Digital In

Enable

24 V → active
0 V → not active

Needed to enable the system with an

external signal.

Ground

4

Signal

1

Digital

Out

Status

Relay

closed → active, system

on

Relay open → not active,

system off

This signal indicates if the system is

active.

Ground

2

Figure 21

– “USER INTERFACE” Connector

-

Delivered with Controller

-

Connector Type: AK1550/06-3.81-Green

Figure 22

– “USER INTERFACE” Pin Numbering