Trebor 55E EVOLVE User Manual
Page 24

PAGE 24
EVOLVE 55E PUMP OPERATION / MAINTENANCE MANUAL
Record the start pressure, Target = 28psig
Pump must prime and even cycling must be achieved before continuing
Increase pressure to 60 psi and allow pump to run for 5 minutes
Check for fluid leaks, listen for air leaks, and check for irregular operation
Close the air supply valve and disconnect the pump
If required, prepare the pump for drying
4.9.b Pump Drying Procedure
Connect vacuum hose to fluid discharge
Connect purge line to fluid inlet
Apply 60 psig air pressure to the fluid inlet
Cycle pump & vacuum dry by rotating pump side to side for 30 seconds.
Turn off Air Supply and allow the pump to purge for 5 minutes.
4.9.c Dry Suction Test
Connect to air supply. See above instructions.
Connect a vacuum capable line with instrumentation to the pump fluid inlet
Apply 20 psig air pressure to the pump (Note: Pump cycling is controlled by the external
control system. The pump will not operate without an operating external controller.)
Measure and record the suction value
Target = 12 in-Hg.