beautypg.com

tekmar 529 Thermostat Installation User Manual

Page 22

background image

22 of 28

© 2011

D 529 - 12/11

Error M

e

s

s

ag

e

s

(

2

of 4

)

Error Messag

e

Descrip

tion

DEVICE LIMIT

The number of de

vices on t

he t

ekmarNe

t

®

bus has e

xceeded 2

4. De

vices include t

ekmarNe

t

®

Thermostats and Se

tpoint Contr

ols. The de

vice count must be lo

w

e

red t

o

2

4

or less. If possible,

mo

ve

de

vices t

o

o

ther t

ekmarNe

t

®

buses.

Err

or clears aut

omatically once t

he number of de

vices on t

he t

ekmarNe

t

®

bus is at 2

4

or lo

w

e

r.

R

OOM SENSOR SHORT CIR

CUIT

The built-in air t

e

mper

atur

e sensor has a shor

t cir

cuit f

ault. Do no

t confuse t

his err

or wit

h t

he auxiliar

y

room sensor shor

t cir

cuit err

o

r.

This err

or canno

t be field r

epair

ed.

Contact y

our wholesaler or t

ekmar sales r

epr

esentativ

e f

or de

tails on r

epair pr

ocedur

es.

R

OOM SENSOR OPEN CIR

CUIT

The built-in air t

e

mperatur

e sensor has an open cir

cuit f

ault. Do no

t confuse t

his err

or wit

h t

h

e

auxiliar

y r

oom sensor shor

t cir

cuit err

o

r.

This err

or canno

t be field r

epair

ed.

Contact y

our wholesaler or t

ekmar sales r

epr

esentativ

e f

or de

tails on r

epair pr

ocedur

es.

A

U

XILIAR

Y R

OOM SENSOR SHORT CIR

CUIT

The auxiliar

y r

oom sensor has a shor

t cir

cuit. Check f

or damaged wir

es. Locat

e and r

epair t

h

e

pr

oblem as described in t

he Data Br

ochur

e D

0

7

6

, D0

77

, or D084.

Err

or clears af

ter t

he auxiliar

y r

oom sensor f

ault is corr

ect

ed.