tekmar 527 Thermostat Installation User Manual
Page 17

17 of 20
© 2011
D 527 - 12/11
Error M
e
s
s
ag
e
s
(
2
of 2
)
Error Messag
e
Descrip
tion
ADDRESS ERR
OR
This t
hermostat and ano
ther de
vice ha
ve
been manually giv
en t
he same t
ekmarNe
t
®
addr
ess.
Err
or clears aut
omatically once t
his t
hermostat is giv
en a ne
w manually se
t addr
ess or if t
he t
hermostat is se
t
to
aut
omatic addr
essing.
R
OOM SENSOR SHORT CIR
CUIT
The built-in air t
e
mperatur
e sensor has a shor
t cir
cuit f
ault.
This err
or canno
t be field r
epair
ed.
Contact y
our wholesaler or t
ekmar sales r
epr
esentativ
e f
or de
tails on r
epair pr
ocedur
es.
R
OOM SENSOR OPEN CIR
CUIT
The built-in air t
e
mperatur
e sensor has an open cir
cuit f
ault.
This err
or canno
t be field r
epair
ed.
Contact y
our wholesaler or t
ekmar sales r
epr
esentativ
e f
or de
tails on r
epair pr
ocedur
es.
AIR GR
OUP MEMBER ERR
OR
The t
h
ermostat has been select
ed t
o
join an air gr
oup as a member
, y
e
t t
h
er
e is no air gr
oup mast
er
thermostat.
Err
or clears once t
he t
hermostat de
tects an air gr
oup mast
er or t
he air gr
oup is se
t t
o
OFF
.
- 032 Timer (4 pages)
- 033 4 Timer (12 pages)
- 040 RDM (4 pages)
- 054 RTU (2 pages)
- 055 RTU (2 pages)
- 060 RTU (2 pages)
- 062 RTU (4 pages)
- 063 RTU (8 pages)
- 070 Outdoor Sensor (4 pages)
- 071 Universal Sensor (4 pages)
- 072 10k Slab Sensor (2 pages)
- 073 10k Slab Sensor (2 pages)
- 076 Indoor Sensor (4 pages)
- 077 Indoor Sensor (4 pages)
- 078 Universal Sensor (4 pages)
- 079 Slab Sensor (4 pages)
- 081 Three Outdoor Sensor Module (4 pages)
- 082 Universal Sensor (4 pages)
- 083 Duct Sensor (4 pages)
- 084 Indoor Sensor (4 pages)
- 085 10k Solar Sensor (2 pages)
- 086 Humidity & Temperature Sensor (8 pages)
- 090 Snow/Ice Sensor (8 pages)
- 095 Snow Sensor (8 pages)
- 150 One Stage Setpoint Control (4 pages)
- 152 Two Stage Setpoint Control (4 pages)
- 153 Mixing Setpoint Control (4 pages)
- 155 Difference Setpoint Control (4 pages)
- 156 Difference Setpoint Control (12 pages)
- 157 Difference Setpoint Control (16 pages)
- 161 Setpoint Control Installation (36 pages)
- 161 Setpoint Control User Manuals (12 pages)
- 162 Setpoint Control Installation (32 pages)
- 162 Setpoint Control User Manuals (12 pages)
- 256 Boiler Control (20 pages)
- 257 DHW Control (12 pages)
- 260 Boiler Control (20 pages)
- 261 Boiler Control (20 pages)
- 262 Boiler Control Installation (36 pages)
- 262 Boiler Control User Manuals (4 pages)
- 263 Boiler Control (36 pages)
- 264 Boiler Control (32 pages)
- 265 Boiler Control (36 pages)
- 268 Boiler Control (32 pages)
- 269 One Stage Steam Control (12 pages)