Installation – tekmar 095 Snow Sensor User Manual
Page 2
© 2013
095_D - 05/13
2 of 8
A Watts Water Technologies Company
Installation
Caution
Improper installation and operation of this control could result in damage to
the equipment and possibly even personal injury or death. It is the installer’s
responsibility to ensure that this control is safely installed according to all
applicable codes and standards. Please follow these step-by-step instructions
to gain a full understanding of this device.
Step 1 - Check the Contents
Check the contents of this package. If any of the contents listed are missing or
damaged, please refer to the Limited Warranty and Product Return Procedure on
the back of this brochure and contact your wholesaler or tekmar sales representative
for assistance.
Type 095 includes • One Snow Sensor 095 • One Installation and Operation
Manual 095_D.
Step 2 - Choosing a Location for the Sensor
The sensor should be installed outside on a nominal 1/2” (16 mm) PVC or rigid
metal conduit pole either on a roof or to the side of the snow melting surface. The
sensor must be located away from trees, building overhangs or other locations
that may interfere with falling snow. Avoid installing in locations where the sensor
may be vandalized. It is best to point the front face of the sensor in the direction
of any prevailing wind.
Roof Mounted
Conduit fastened to
fascia board
Ground Mounted
Conduit run under-
ground with a pole
above surface
Roof Mounted
Ensure water-proof
installation with flashing
boot or similar method