WARNING:

Casing hole filler cap must be installed in

blower shelf hole when condensate trap is relocated.
Failure to follow this warning could result in electrical
shock, fire, personal injury or death.

4. Install condensate trap into left-hand side casing hole by

inserting tube connection stubs through casing hole and
rotating until tabs snap into locking position.

5. Fill unused condenstate trap casing holes with plastic filler

caps (factory-supplied in loose parts bag).

D.

Condensate Trap Tubing (Alternate Upflow

Orientation)

NOTE:

See Fig. 8 or tube routing label on main furnace door to

confirm location of these tubes.

1. Collector Box Drain Tube

Connect collector box drain tube (blue label) to condensate
trap.

NOTE:

On 17-1/2-in. wide furnaces ONLY, cut tube between

corrugated sections to prevent kinks.

2. Inducer Housing Drain Tube

a. Remove and discard LOWER (molded) inducer housing

drain tube which was previously connected to conden-
sate trap.

b. Use inducer housing drain extension tube (violet label

and factory-supplied in loose parts bag) to connect
LOWER inducer housing drain connection to conden-
sate trap.

c. Determine appropriate length, cut, and connect tube.

d. Clamp tube to prevent any condensate leakage.

3. Relief Port Tube

a. Connect relief port tube (green label) to condensate trap.

b. Extend this tube (if required) by splicing to small

diameter tube (factory-supplied in loose parts bag).

c. Determine appropriate length, cut, and connect tube.

E.

Condensate Trap Field Drain Attachment

Refer to Condensate Drain section for recommendations and
procedures.

F.

Pressure Switch Tubing

The LOWER collector box pressure tube (pink label) is factory
connected to the pressure switch and should not require any
modification.

NOTE:

See Fig. 7 or 8 or tube routing label on main furnace door

to check for proper connections.

Fig. 7—Factory-Shipped Upflow Tube Configuration

(Shown With Blower Access Panel Removed)

A94213

COLLECTOR BOX

TUBE (PINK)

COLLECTOR BOX

TUBE (GREEN)

INDUCER HOUSING

(MOLDED) DRAIN

TUBE (BEHIND

COLLECTOR BOX

DRAIN TUBE)

COLLECTOR BOX

DRAIN TUBE (BLUE)

FIELD-INSTALLED

FACTORY-SUPPLIED

DRAIN TUBE

COUPLING (LEFT

DRAIN OPTION)

FIELD-INSTALLED

FACTORY-SUPPLIED

DRAIN TUBE

FIELD-INSTALLED

FACTORY-SUPPLIED

DRAIN TUBE

COUPLING (RIGHT

DRAIN OPTION)

CAP

COLLECTOR BOX

DRAIN TUBE (BLUE

& WHITE STRIPED)

PLUG

FIELD-INSTALLED

FACTORY-SUPPLIED

1

2

-IN. CPVC STREET

ELBOWS (2) FOR

LEFT DRAIN OPTION

CONDENSATE
TRAP

Fig. 8—Alternate Upflow Tube Configuration and

Trap Location

A94214

COLLECTOR BOX

TUBE (PINK)

CONDENSATE

TRAP

COLLECTOR BOX

TUBE (GREEN)

COLLECTOR BOX

DRAIN TUBE (GREEN)

INDUCER

HOUSING

DRAIN TUBE

(VIOLET)

CAP

COLLECTOR BOX

DRAIN TUBE (BLUE

& WHITE STRIPED)

PLUG

—7—