These furnaces are shipped with the following materials to assist in
proper furnace installation. These materials are shipped in the main
blower compartment.

Installer Packet includes:

Installation, Start-Up, and Operating Instructions
Service and Maintenance Procedures

User’s Information Manual
Warranty Certificate

Loose Parts Bag includes:

Quantity

Pressure tube extension

1

Collector box or condensate trap extension tube

1

Inducer housing drain tube

1

1/2-in. CPVC street elbow

2

Drain tube coupling

1

Drain tube coupling grommet

1

Vent and combustion-air pipe support

2

Fig. 3—Clearances to Combustibles

A02250

Clearance in inches.

Vent clearance to

combustibles 0".

This furnace is approved for UPFLOW, DOWNFLOW and
HORIZONTAL installations.

*

BO

T

T

O

M

0"

Ø

3"

0"

§

0"

T

O

P/

PLE

N

U

M

1"

0"

§

30

MIN

ALL POSITIONS:

S I

D E

F

R

O

N

T

B

C

K

A

S

E

R V

I

E

C

F R

ON

T

S I

D E

U

F

R N

A C

E

Clearance arrows
do not change with
furnace orientation.

328068-201 REV. A
LIT - TOP

MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION

HORIZONTAL POSITIONS:

DOWNFLOW POSITIONS:

§

Ø

*

Mimimum front clearance for service 30 inches (762mm).

This forced air furnace is equipped for use with natural gas at altitudes 0 - 10,000 ft (0 - 3,050m), except 140 size furnaces are only approved for altitudes 0 - 7,000 ft.

(0 - 2,135m).
An accessory kit, supplied by the manufacturer, shall be used to convert to propane gas use or may be required for some natural gas applications.
This furnace is for indoor installation in a building constructed on site. This furnace may be installed in a manufactured (mobile) home when stated on rating plate and
using factory authorized kit.
This furnace may be installed on combustible flooring in alcove or closet at Minimum Inches Clearance To Combustible Construction as described below.

This furnace requires a special venting system. Refer to the installation instructions for parts list and method of installation. This furnace is for use with schedule-40 PVC,
PVC-DWV, CPVC, or ABS-DWV pipe, and must not be vented in common with other gas-fired appliances. Construction through which vent/air intake pipes may be
installed is maximum 24 inches (600 mm), minimum 3/4 inches (19 mm) thickness (including roofing materials).

UPFLOW OR
DOWNFLOW

1/2" MAX

LEVEL (0")TO

For upflow and downflow applications, furnace must be installed level, or pitched within 1/2" of level. For a

horizontal application, the furnace must be pitched minimum 1/4" to maximum of 1/2" forward for proper

drainage. See Installation Manual for IMPORTANT unit support details on horizontal applications.

HORIZONTAL

MIN 1/4" TO 1/2" MAX

For installation on combustible floors only when installed on special base No.
KGASB0201ALL, Coil Assembly, Part No. CD5 or CK5, or Coil Casing, Part No. KCAKC.

Line contact is permissible only between lines formed by intersections of top and two sides
of furnace jacket, and building joists, studs, or framing.
Clearance shown is for air inlet and air outlet ends.
120 size furnace requires 1 inch bottom clearance to combustible materials.

FRONT

FRONT

INSTALLATION

Fig. 4—Return-Air Temperature

A93042

Fig. 5—Installation in a Garage

A93044

18-IN. MINIMUM

TO BURNERS

—4—