Bryant Deluxe 4-Way Multipoise Variable-Capacity Direct-Vent Condensing Gas 355MAV User Manual

Installation, start-up, and operating instructions, 355mav series h

background image

NOTE:

Read the entire instruction manual before starting the

installation.

This symbol

indicates a change since the last issue.

Index

Page

DIMENSIONAL DRAWING........................................................3
SAFETY CONSIDERATIONS..................................................2-5

Clearances to Combustibles......................................................4

ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS........5
INTRODUCTION ..........................................................................5
APPLICATIONS ......................................................................5-12

General ......................................................................................5
Upflow Applications..............................................................5-8
Downflow Applications.........................................................8-9
Horizontal Left (Supply-Air Discharge) Applications .......9-11
Horizontal Right (Supply-Air Discharge) Applications ...11-12

LOCATION ............................................................................13-14

General ....................................................................................13
Low-Heat Only Installation ....................................................13
Furnace Location Relative to Cooling Equipment ................14
Hazardous Locations...............................................................14

INSTALLATION....................................................................14-16

Leveling Legs (If Desired) .....................................................14
Installation In Upflow or Downflow Applications................14
Installation In Horizontal Applications.............................14-16

AIR DUCTS............................................................................16-19

General Requirements .......................................................16-17
Ductwork Acoustical Treatment.............................................17
Supply Air Connections..........................................................17
Return Air Connections ..........................................................17
Filter Arrangement..................................................................17
Bottom Closure Panel........................................................17-18
Gas Piping..........................................................................18-19

ELECTRICAL CONNECTIONS...........................................19-21

115-v Wiring...........................................................................19
24-v Wiring.............................................................................20
Accessories ........................................................................20-21

DIRECT VENTING ...............................................................21-31

Removal of Existing Furnaces from

Common Vent Systems.....................................................21

Combustion-Air and Vent Piping .....................................21-29
Concentric Vent and Combustion-Air Termination

Kit Installation ...................................................................29

Multiventing and Vent Terminations................................29-31

CONDENSATE DRAIN..............................................................31

General ....................................................................................31

Application ..............................................................................31
Condensate Drain Protection ..................................................31

SEQUENCE OF OPERATION..............................................31-36

Single-Stage Thermostat and Two-Stage Heating
(Adaptive Mode)................................................................33-34
Two-Stage Thermostat and Two-Stage Heating....................34
Cooling Mode ....................................................................34-35
Thermidistat Mode..................................................................35
Super-Dehumidify Mode...................................................35-36
Continuous Blower Mode.......................................................36
Heat Pump...............................................................................36
Component Test ......................................................................36

START-UP PROCEDURES ..................................................36-45

General ....................................................................................36
Select Setup Switch Positions...........................................36-39
Prime Condensate Trap With Water ......................................39
Purge Gas Lines......................................................................39
Adjustments .......................................................................39-45
Set Gas Input Rate ............................................................39-42
Set Temperature Rise..............................................................42
Set Thermostat Heat Anticipator ......................................42-45

CHECK SAFETY CONTROLS ............................................45-46

A93040

ama

CERTIFIED

As an ENERGY STAR®
Partner, Bryant Heating &
Cooling Systems has de-
termined that this product
meets

the

ENERGY

STAR® guidelines for en-
ergy efficiency.

REGISTERED QUALITY SYSTEM

Fig. 1—Multipoise Orientations

A93041

UPFLOW

DOWNFLOW

HORIZONTAL

LEFT

AIRFLOW

AIRFLOW

AIRFLOW

AIRFLOW

HORIZONTAL

RIGHT

installation, start-up,
and operating instructions

DELUXE 4-WAY MULTIPOISE
VARIABLE-CAPACITY DIRECT-VENT
CONDENSING GAS FURNACE

Cancels:

II 355M-40-9

II 355M-40-10

12-02

355MAV

Series H

—1—