Valve Specifications

Working Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-120 psi (1.38 - 8.27 bar)
Standard 12 Volt Transformer Input Electrical Rating . . . . . . . . . . . . . . . . . . . . . 115V 60 Hz
Optional 12 Volt Transformer Input Electrical Rating . . . . . . . . . . 115V 50 Hz, 230V 50 Hz,

230V 60 Hz, 100V 60 Hz, 100V 50 Hz

Operating Ambient Temperature. . . . . . . . . . . . . . . . . . . . . 34

° F to 120 ° F (1 ° C to 49 ° C)

Operating Water Temperature. . . . . . . . . . . . . . . . . . . . . . . 34

° F to 100 ° F (1 ° C to 38 ° C)

13. System using

more or less salt
than salt control is
set for.

a. Inaccurate setting.
b. Foreign matter in

controller causing
incorrect flow rates.

c. Defective controller.

a. Make correct setting.
b. Remove variable salt

controller and flush out
foreign matter. Manually
position control to brine draw
to clean controller (after so
doing, position control to
“purge” to remove brine from
tank).

c. Replace defective part.

(Contact dealer.)

14. Intermittent or

irregular brine
draw.

a. Low water pressure.

b. Defective injector !

a. Set pump to maintain at

least 20 psi (1.38 bar) at
softener.

b. Replace both injector and

injector cap. (Contact
dealer.)

15. No conditioned

water after
regeneration.

a. Unit did not regenerate.
b. No salt in brine tank.
c. Plugged injector !

d. Air check valve closed

prematurely.

a. Check for power.
b. Add salt to brine tank.
c. Remove injector and flush it

and injector screen.

d. Put control momentarily into

refill to free air check.
Replace or repair air check if
needed. (Contact dealer.)

Problem

Possible Cause

Solution