31

10. Control will not

regenerate
automatically but
will regenerate
when button is
pressed.

a. If water flow display is not

operative, refer to Item 5.

b. Defective circuit board.

c. Incorrect hardness and

capacity settings.

a. Same as Item 5.

b. Replace timer. (Contact

dealer.)

c. Set to correct values. See

Programming section.

11. Run out of soft

water between
regenerations.

a. Improper regeneration.

b. Incorrect salt setting.

c. Incorrect hardness or

capacity settings.

d. Water hardness has

increased.

e. Restricted meter turbine

rotation due to foreign
material in meter !

a. Repeat regeneration,

making certain that correct
salt dosage is used.

b. Set salt control to proper

level. See salt setting chart.

c. Set to correct values. See

Programming section.

d. Set hardness to new value.

See Programming section.

e. Remove meter housing, free

up turbine and flush with
clean water. Turbine should
spin freely; if not, replace
meter. (Contact dealer.)

12. Brine tank

overflow.

a. Brine valve disc 1 being

held open by foreign
matter.

b. Uncontrolled brine refill

flow rate.

c. Valve disc 2 not closed

during brine draw causing
brine refill.

d. Air leak in brine line to air

check.

e. Improper drain control for

injector.

f.

Drain control clogged
with resin or other debris.

a. Manually operate valve stem

to flush away obstruction.

b. Remove variable salt

controller to clean it and the
ball.

c. Flush out foreign matter

holding disc open by
manually operating valve
stem.

d. Check all connections in

brine line for leaks. Refer to
instructions.

e. Too small of a drain control

with a “B” or “C” injector will
reduce draw rates.
Reference Pressure
Graphs.

f.

Clean drain control.

Problem

Possible Cause

Solution

1018075 Rev I.fm Page 31 Tuesday, February 17, 2004 4:26 PM