6. Control

regenerates at
wrong time of day.

a. Power outages.

b. Clock set incorrectly.

a. Reset clock to correct time of

day.

b. Reset clock to correct time of

day.

7. Timer stalled in

regeneration
cycle.

a. Motor dead.

b. Motor runs backward.

c. No electric power at

outlet.

d. Broken gear.

e. Defective switch.

f.

Air leak in brine
connections.

g. Binding of camshaft.

h. Water pressure greater

than 125 psi (8.6 bar)
during regeneration !

i.

Defective circuit board.

a. Replace timer. (Contact

dealer.)

b. Replace timer. (Contact

dealer.)

c. Repair outlet or use working

outlet.

d. Replace timer. (Contact

dealer.)

e. Replace timer. (Contact

dealer.)

f.

Check all junction points and
make appropriate
corrections.

g. Remove foreign object

obstruction from valve discs
or camshaft.

h. Install pressure regulator.

i.

Replace timer. (Contact
dealer.)

8. Continuous

regeneration.
Camshaft does
not stop at the end
of regeneration.

a. Broken switch actuator

on gear.

b. Defective switch.

a. Replace timer. (Contact

dealer.)

b. Replace timer. (Contact

dealer.)

9. Control will not

regenerate
automatically or
when button is
pressed.

a. Electric cord or

transformer unplugged.

b. No electric power at

outlet.

c. Defective motor.

d. Broken gear.

e. Binding in gear train.

f.

Defective switch.

a. Connect power.

b. Repair outlet or use working

outlet.

c. Replace timer. (Contact

dealer.)

d. Replace timer. (Contact

dealer.)

e. Replace timer. (Contact

dealer.)

f.

Replace timer. (Contact
dealer.)

Problem

Possible Cause

Solution