AR60X Installation Manual 

29 

580­00517, rev B 

5  Connecting Network Equipment 

The user networking equipment that is connected to the radio should be checked to ensure it operates 
properly over a wired connection.  Once this has been confirmed this will save troubleshooting steps 
after the radio is installed and connected to the network equipment. 

We recommend the network equipment on both sides of the link be configured as follows:

·  1000 Mbps full­duplex

·  Port auto­negotiation and flow control enabled

·  Port configured to not enter error­disable state due to link up/down transitions 

(since these may occur during periods of very heavy rain) 

It is possible to disable auto­negotiation on the radio’s fiber 
interface by use of the built­in Network Management interface. 
The radio’s 10/100Base­T port is permanently set to auto­ 
negotiate. 

5.1  Network Port Statistics 

In the event the network equipment connected to the AR60X offers the capability below, we 
recommend you verify the following on the network equipment:

·  Link integrity

·  There are no receive errors on the link

·  Network traffic is flowing in both directions. 

The radios support all standard Ethernet frame sizes, up to 1632 
bytes for un­tagged or 802.1q VLAN­tagged frames.