HANGING INSTRUCTIONS FOR FIXTURES THAT WEIGHT MORE THAN 50LBS
FRIS19-50R
SAFETY WARNING:
Read wiring and grounding instructions [FRIS 18]
and any additional directions. Turn power supply off during installation. If new wiring
is required, consult a qualified electrician or local authorities for code requirements.
STEP 1
1
Shut off electrical current before starting. If the fixture you are replacing is
turned on and off by a wall switch, simply turn the switch off. If not, remove the
appropriate fuse (or open the circut breakers) until the fixture is dead.
• DO NOT restore current - either by fuse, breaker or switch - until the new
fixture is completely wired and in place.
2
Supply wires shall enter the outlet box (a) through any knockout EXCEPT the top
center knockout - See Drawing 1.
STEP 2
1
Fixture is to be mounted by a 3/8 steel pipe with 3/8 -18 NPSM thread, 3/4”
threads at both ends (not supplied). Pipe should be anchored to structure or
bridging member with sufficient strength to support 4 times the fixtures
weight - see Drawing 2.
2
Adjust pipe so 1/2” of 3/8 steel pipe extends into the junction box, at the center
knock out.
3
Please refer to the back of this sheet to the safety cable installation instructions
and ONLY complete steps 1 and 2 at this time.
STEP 3
1
Thread pipe coupler (b) onto protruding pipe inside outlet box. Secure in place
by tightening allen head screw (c) -
see Drawing 1 .
2
Thread hexnut (d) onto threaded nipple (e). Thread nipple (e) into coupler (b).
Secure in place by tightening hexnut (d) against coupler (b) and then tightening
allen screw (f) .
3
thread hexnut (j) onto nipple (e). DO NOT tighten hexnut
(h) at this time.
4
Thread screw collar loop (k)
Adjust screw collar loop height so the half of the exterior thread on
screw collar loop (k) is exposed when canopy (l) is held up to the ceiling.
STEP 4
1
Determine length of chain you will require. Attach one end of length of chain to
fixture.
2
Slip threaded ring (m) and canopy (l) onto chain - see Drawing 1.
3
Attach fixture with chain to screw collar loop (k). Please get assistance, weight
and size of fixture is difficult to manage alone.
4
Weave ground wire, supply wire, and safety cable through chain, up through center
of screw collar loop (k), through center of nipple (e) , and out the opening on the
side of coupler (b).
[DRAWING 1]
[DRAWING 2]
5.28.08
800.421.3517 WWW.FREDRICKRAMOND.COM
ceiling
joist
ceiling
joist
support
block
junction
box
bridge
supply wire
hex nut
3/8 steel pipe
a
b
c
f
d
e
l
m
top center
knockout
3/8 steel pipe
h
j
k
wire
safety
cable
ground
wire
onto end of nipple (e)
5
After screw collar loop (k) is adjusted properly , tighten hex nut (j) against