Performance curves, Dimensions – Banner WORLD-BEAM QS30 Water Sensor User Manual
Page 6

Performance Curves
Excess Gain
Beam Pattern
H2O Thickness vs. Excess Gain
100
1.0 m
(3.3')
10 m
(33')
0.1 m
(0.3')
1000
10000
100000
1000000
E
X
C
E
S
S
G
A
I
N
DISTANCE
QS30
Opposed Mode
Water Sensor
High Gain
Super
High
Power
Low Gain
8.0 m
(24')
4.0 m
(12')
6.0 m
(18')
2.0 m
(6')
0
0
150 mm
300 mm
450 mm
150 mm
300 mm
450 mm
0
6"
12"
18"
6"
12"
18"
DISTANCE
High Gain
Low Gain
QS30
Opposed Mode
Water Sensor
Super
High
Power
(Typical for Distilled Water, 100% Blocked
Condition)
0
1
10
100
1000
20
40
60
80
100
120
10000
100000
H
2
O
Thickness (mm)
Excess Gain
Dimensions
1.4 mm
(0.05")
44.0 mm
(1.73")
8.9 mm
(0.35")
33.0 mm
(1.30")
5.5 mm
(0.22")
51.1 mm
(2.01")
54.3 mm
(2.14")
22.0 mm
(0.87")
M30 x 1.5 Thread
max. torque 6 Nm (53 in lbs)
with included
30 mm mounting nut
2 x ø3.3 mm (0.13")
max. torque
0.7 Nm (6 in lbs)
Yellow LED
Output
Indicator
Yellow and Green LEDs
Hardware included:
(2) M3 x 0.5 x 28 stainless steel
machine screws, nuts and washers
Aperture Kit APQS30-DVH
12.5 mm
(0.47")
16 mm
(0.63")
WORLD-BEAM QS30H2O Series
6
www.bannerengineering.com - tel: 763-544-3164
P/N 136166 rev. C