Banner WORLD-BEAM QS30 Water Sensor User Manual
Page 4

Step
Remote Line
0.04 seconds < T < 0.8 seconds
Result
Access TEACH Mode/
Learn 1st Condition
• Present 1st condition.
• Single-pulse remote TEACH line.
T
1x
Power LED: OFF
AID LED: Double-flash
Learn 2nd Condition
• Present 2nd condition.
• Single-pulse remote TEACH line.
T
1x
TEACH Accepted
Power LED: Flashes 3 times, then ON
AID LED: AID mode (flash rate varies depending
upon signal strength)
Sensor returns to RUN mode.
TEACH Not Accepted
Power LED: OFF
AID LED: Single-flash
Sensor returns to “Learn 1st Condition.”
Restore Factory Default (Maximum Contrast) Setting
Step
Remote Line
0.04 seconds < T < 0.8 seconds
Result
Access TEACH Mode
• Single-pulse remote TEACH line
T
1x
Power LED: OFF
AID LED: Double-flash
Restore Factory Default Setting
(Maximum Contrast Setting)
• Double-pulse remote TEACH line
T
T
T
2x
Power LED: Flashes 3 times, then ON
AID LED: AID mode (flash rate varies depend-
ing upon signal strength)
Sensor returns to RUN mode with maximum
contrast setting.
Analog Output Slope Invert
Teach sensing limits before inverting the output slope.
Step
Remote Line
0.04 seconds < T < 0.8 seconds
Result
Toggle Analog Output Slope
• Triple-pulse remote TEACH line
T
T
T
T
T
3x
Analog output slope toggles between positive
and negative.
WORLD-BEAM QS30H2O Series
4
www.bannerengineering.com - tel: 763-544-3164
P/N 136166 rev. C