Performance curves, Dimensions, Figure 1. excess gain curve – Banner WORLD-BEAM QS30 Series User Manual
Page 9: Figure 2. beam pattern, Cabled models qd models

Environmental
Certifications
Rating
IP67, NEMA 6
Operating Conditions
Temperature: -10 to +55 °C (+14 to 122 °F)
Max. relative humidity: 90% @ 55 °C (non-condensing)
Vibration and Mechanical Shock
All models meet Mil. Std. 202F requirements. Method
201A (Vibration: 10 to 60 Hz max. double amplitude
0.06", maximum acceleration 10G). Also meets IEC
947-5-2 requirements: 30G, 11 ms duration, half sine
wave.
Performance Curves
Performance curves are based on the use of a 90% reflectance white test card.
1
10
100
1000
10000
E
X
C
E
S
S
G
A
I
N
DISTANCE
10 mm
(0.4")
100 mm
(3.9")
1000 mm
(39.4")
10000 mm
(393.7")
QS30EDV Series
High Speed
Normal Speed
Figure 1. Excess Gain Curve
1500 mm
(59.0")
1200 mm
(47.2")
900 mm
(35.4")
600 mm
(23.6")
300 mm
(11.8")
0
0
-4 mm
-8 mm
-12 mm
4 mm
8 mm
12 mm
0
-0.16"
-0.31"
-0.47"
0.16"
0.31"
0.47"
DISTANCE
QS30EDV Series
High Speed
Normal Speed
B
E
A
M
W
I
D
T
H
Figure 2. Beam Pattern
Dimensions
Cabled Models
QD Models
22.0 mm
(0.87")
5.0 mm
(0.20")
32.5 mm
(1.28")
LO
HS
static
dynamic
DO
33.0 mm
(1.30")
Emitter
28.8 mm
(1.13")
Receiver
17.6 mm
(0.69")
12.5 mm
(0.49")
3.5 mm
(0.14")
44.0 mm
(1.73")
1.3 mm
(0.05")
13.0 mm
(0.51")
35.0 mm
(1.38")
2 x ø3.3 mm (0.125")
max. torque
0.7 Nm (6 in lbs)
M30 x 1.5 Thread
max. torque
6 Nm (53 in lbs)
with included 30 mm
mounting nut
WORLD-BEAM QS30EDV Expert Diffuse-Mode Sensor
P/N 127755 Rev. C
www.bannerengineering.com - tel: 763-544-3164