Bar Graph LED (Following TEACH)
Relative Signal Difference/Recommendation
1
Unreliable: Consider an alternate sensing scheme.
Push Button
Remote Line
Result
Access Dynamic
TEACH Mode
Press and hold Dynamic (+)
push button for more than 2
seconds
Hold the remote line low (to
ground) for more than 2 sec-
onds
Power LED: OFF
Output LED: OFF
Bargraph: #7 and 8 alternately flash
TEACH Sensing
Conditions
Continue to hold push button
(+) and present the Output ON
and OFF conditions
Continue to hold remote line
low (to ground) and present
the Output ON and OFF con-
ditions
Power LED: OFF
Output LED: OFF
Bargraph: #7 and 8 alternately flash
Return to Run
Mode
Release push button (+)
Release the remote line/
switch
TEACH Accepted
Power LED: ON
Bargraph: One LED flashes to show relative con-
trast (good signal difference shown; see table
above)
Sensor returns to RUN mode with new settings
TEACH Unacceptable
Power LED: OFF
Bargraph: #1, 3 and 5, 7 alternately flash to show
failure
Sensor returns to RUN mode without changing
settings
Single-Point Window Set
• Sets a single ON condition that extends 12.5% above and below the taught condi-
tion.
• All other conditions (lighter or darker) result in OFF output
• Sensing window size (sensitivity) is adjustable using the “+” and “-” buttons (Manual
Adjust)
• Recommended for applications where the target to be sensed may not always ap-
pear in the same place, or when other signals may appear.
Single-Point Set designates a sensing window, by setting two switching thresholds at
12.5% above and below the presented condition. The Output ON condition is inside the
window, and the Output OFF conditions are outside the window when Light Operate is
selected. Output ON and OFF conditions can be reversed by changing Light/Dark Op-
erate status in Setup mode.
Sensor positions
window thresholds
12.5% from the
presented condition
Darkest
(no signal)
Most Light
(saturated
signal)
Condition
Presented
Sensing window size
adjusted by
Manual Adjust
Output OFF
Output OFF
Output ON
Single-Point Window Set and Manual Adjust
Using Manual Adjust with Single-Point Window Set expands or contracts the size of the window. The lighted LEDs on the light bar sepa-
rate to a greater or lesser extent to exhibit the relative sensing window size.
WORLD-BEAM QS30EDV Expert Diffuse-Mode Sensor
4
www.bannerengineering.com - tel: 763-544-3164
P/N 127755 Rev. C