Single-point light set – Banner WORLD-BEAM QS30 Series User Manual
Page 5

Push Button
Remote Line
Result
0.04 seconds ≤ “Click” ≤
0.8 seconds
0.04 seconds ≤ T ≤ 0.8
seconds
Access Set Mode
Press and hold Static (-)
push button for more than 2
seconds
Single-pulse the remote line
Power LED: OFF
Output LED: ON (Push Button)
Output LED: OFF (Remote)
Bar graph: #5 and 6 alternately flash
Set Sensing Con-
dition
Present the sensing condi-
tion and double-click the
Static (-) push button
Present the sensing condi-
tion and double-pulse the re-
mote line
Threshold Conditions Accepted
Power LED: ON
Bar graph: 2 indicators flash together to show the
threshold conditions are accepted
Sensor returns to RUN mode with new settings
Threshold Conditions Unacceptable
Power LED: OFF
Bar graph: #1, 3 and 5, 7 alternately flash to show
failure
Sensor returns to “SET Sensing Condition”
Single-Point Light Set
• Sets a threshold 12.5% below the taught condition.
• Any condition darker than the threshold condition causes the output to change
state.
• Threshold position is adjustable using the “+” and “-” buttons (Manual Adjust).
• Recommended for applications where only one condition is known, for example
a stable light background with varying darker targets.
A single sensing condition is presented, and the sensor positions a threshold 12.5%
below the presented condition. When a condition darker than the threshold is
sensed, the output either turns ON or OFF, depending on the Light/Dark Operate
setting (see
on page 6).
Threshold position
adjusted by
Manual Adjust
Sensor positions
threshold 12.5% below
the presented condition
Darkest
(no signal)
Most Light
(saturated
signal)
Output OFF
Output ON
Condition
Presented
Light Set and Light/Dark Operate Selection
In Light Operate mode, Light Set teaches the Output ON condition. In Dark Operate mode, Light Set teaches the Output OFF condition.
Push Button
Remote Line
Result
0.04 seconds ≤ “Click” ≤
0.8 seconds
0.04 seconds ≤ T ≤ 0.8
seconds
Access Set Mode
Press and hold Static (-)
push button for more than 2
seconds
Single-pulse the remote
line
Power LED: OFF
Output LED: ON (Push Button)
Output LED: OFF (Remote)
Bar graph: #5 and 6 alternately flash
Set Sensing Condi-
tion
Present the sensing condi-
tion and click the Static (-)
push button four times
Present the sensing con-
dition and four-pulse the
remote line
Threshold Condition Accepted
Power LED: ON
Bar graph: Indicators #5–8 flash together to show that
the threshold condition is accepted
Sensor returns to RUN mode with new settings
WORLD-BEAM QS30EDV Expert Diffuse-Mode Sensor
P/N 127755 Rev. C
www.bannerengineering.com - tel: 763-544-3164
5