R55 expert, Color mark sensors, Setup mode – Banner R55E Series User Manual
Page 7: Locking out (disabling) the push buttons
![background image](/manuals/587555/7/background.png)
R55
Expert
™
Color Mark Sensors
P/N 59574 rev. B
Banner Engineering Corp. • Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
SETUP Mode
SETUP mode is used to configure discrete sensor output response for:
• Light or Dark operate
• 20- or 40-millisecond pulse stretcher (OFF-delay), if required.
It will be necessary to access SETUP mode only if the settings that result from
TEACH mode are not the settings required for the application. The status LEDs indicate
the output response configuration when the sensor is in RUN mode (see table below).
To change the output response settings;
1. Press and hold both push buttons for at least two seconds (or double-pulse the
remote line), until the signal strength light bar turns OFF.
2. Click either push button (or pulse the remote line) to toggle through the six possible
settings, indicated as follows:
SETUP
DO
LO
OFF
Delay
Switch Point
+
DYNAMIC
–
STATIC
Press and Hold
both push buttons
≥ 2 seconds
Figure 5. SETUP Mode
3. Press and hold both push buttons (or hold the remote line) until the signal strength
light bar turns ON, indicating return to RUN mode.
NOTE: If SETUP mode configuration is interrupted and remains inactive for 30 seconds,
the sensor returns to RUN mode with the most recent settings (i.e., exits and
saves current selection).
Locking Out (Disabling) the Push Buttons
In addition to its configuration function, the remote input may be used to disable the push
buttons for security. Disabling the push buttons prevents undesired tampering with the
configuration settings. Connect the gray wire of the sensor as described on page 3, and
four-pulse to either enable or disable the push buttons:
NOTE: Push buttons can be disabled/enabled from the remote line only.
Output Configuration
Delay
Indicator
LO
Indicator
DO
Indicator
Light operate with no delay
OFF
ON
OFF
Light operate with 20 ms delay
Flashing
ON
OFF
Light operate with 40 ms delay
ON
ON
OFF
Dark operate with no delay
OFF
OFF
ON
Dark operate with 20 ms delay
Flashing
OFF
ON
Dark operate with 40 ms delay
ON
OFF
ON
T