R55 expert, Color mark sensors, Window set – Banner R55E Series User Manual
Page 6: Window set and manual adjust
R55
Expert
™
Color Mark Sensors
P/N 59574 rev. B
Banner Engineering Corp. • Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
Window SET
• Establishes a single ON condition
• All other conditions (lighter or darker) result in OFF output
• Sensing window size (sensitivity) is adjustable using “+” and “-” buttons
(Manual Adjust)
The R55 Expert sensor also may be configured for a single specific target. Window SET
is most useful when a product may not always appear in the same place, or when other
signals may appear. Window SET designates a sensing window, with the Output ON
condition inside the window, and the Output OFF conditions outside the window (see
Figure 4). The sensor accepts a single sensing condition and adds switching thresholds
above and below that condition to create a sensing window. Output ON and OFF
conditions can be reversed by changing Light/Dark Operate status in SETUP mode.
Window SET and Manual Adjust
Using Manual Adjust with Window SET expands or contracts the size of the window. The
lighted LEDs on the light bar separate to a greater or lesser extent to exhibit the relative
sensing window size.
Manually adjust the sensitivity by clicking either the “+” or “-” button; the bar graph will
flash two segments centered about the sensing point. If the sensitivity is increased (-),
the two lighted segments will become closer together, and farther apart if the sensitivity
decreased (+). If segments do not flash while the sensitivity is being adjusted, the setting
has reached its maximum and cannot be adjusted further.
Figure 4. Window SET (Light Operate
shown)
Sensor positions
threshold midway
between taught conditions
Sensor positions
threshold midway
between taught conditions
Darkest
(no signal)
Darkest
(no signal)
Most Light
(saturated
signal)
Most Light
(saturated
signal)
Single
sensing
condition
Sensing window size
adjusted by
Manual Adjust
Output OFF
Output OFF
Output OFF
Output ON
Output ON
Darkest Taught
Condition
Lightest Taught
Condition
Position
adjusted by
Manual Adjust
Darkest
(no signal)
Most Light
(saturated
signal)
Output OFF
Output ON
2nd Taught
Condition
1st Taught
Condition
Position
adjusted by
Manual Adjust
Push Button
0.04 seconds ≤ “Click” ≤ 0.8 seconds
Remote Line
0.04 seconds ≤ T ≤ 0.8 seconds
Result
Ac
ce
ss
SE
T
M
od
e
• Press and hold Static button
≥ 2 seconds until LO and DO
indicators alternately flash.
• Release button.
• No action required; sensor is
ready for sensing condition to be
presented.
LO and DO: Alternately flash green
: ON yellow (indicating ready to teach Output ON
condition)
Light Bar: Goes OFF
Le
ar
n
Sw
itc
hp
oi
nt
(O
ut
pu
t O
N
Co
nd
iti
on
)
• Present the Output ON sensing
condition.
• Double-click Static button.
• Present the target (output ON)
condition.
• Single-pulse the remote wire.
• Wait ≥ 0.8 second, then double-
pulse the remote wire.
LO and DO: ON depending on condition taught
: OFF
Light Bar: Two center segments are lit if TEACH was
successful.
+