Valu-beam 915 series, Sensors with electromechanical relay output – Banner VALU-BEAM Series User Manual
Page 10
Dimension Drawing
ADJUSTMENTS: SENSITIVITY control on rear of sensor allows
precise gain setting (turn clockwise to increase gain).
INDICATOR LED: top-mounted red LED indicator lights when-
ever the sensor sees a "light" condition. Models SMA91E and
SMA91ESR emitters have a visible-red "tracer beam" which indicates
"power on" and enables easy "line-of-sight" alignment.
OPERATING TEMPERATURE RANGE: -40 to +50 degrees C
(-40 to +122 degrees F).
VALU-BEAM 915 Series sensors have all of the ruggedness
and versatility of VALU-BEAM sensors, but with an internal
single-pole, double-throw electromechanical output relay.
SMW915 Series sensors operate from 12-28V ac or dc. SMA-
915 Series sensors operate from 90 to 130V ac; SMB915 Series
sensors from 210 to 250V ac. Remaining specifications (below)
are identical for all three series.
Specifications: SMW915, SMA915, and SMB915
Series VALU-BEAM Sensors
SUPPLY VOLTAGE (SMW915 series): 12 to 28V ac or dc at 50mA
maximum, exclusive of load, except for SMA91E and ESR emitters,
which operate from 10-250V ac (50-60Hz) or dc (10mA max.).
SUPPLY VOLTAGE (SMA915 series): 90 to 130V ac (50-60Hz),
20mA maximum, exclusive of load, except for SMA91E and ESR
emitters, which operate from 10-250V ac (50-60Hz) or dc (10mA
max.).
SUPPLY VOLTAGE (SMB915 series): 210 to 250V ac (50-60Hz),
20mA maximum, exclusive of load, except for SMA91E and ESR
emitters, which operate from 10-250V ac (50-60Hz) or dc (10mA
max.).
OUTPUT CONFIGURATION: one internal "form C" (single- pole
double-throw) electromechanical relay.
OUTPUT RATING: max. switching power (resistive load) = 150W,
600VA. Max. switching voltage (resistive load) = 250V ac or 30V dc
(120V ac max. per UL & CSA). Max. switching current (resistive
load) = 5A. Minimum voltage and current = 1 amp at 5V dc, 0.1 amp
at 24V dc. Peak switching voltage = 750Vac (transient suppression
recommended). Mechanical life of relay = 10,000,000 operations.
RESPONSE TIME: 20 milliseconds ON and OFF. 100-millisecond
delay on power-up (relay de-energized during this period).
CONSTRUCTION: reinforced black VALOX
®
housing, totally en-
capsulated, molded acrylic lenses, stainless steel hardware. Meets
NEMA standards 1, 2, 3, 3S, 4, 4X, 12, and 13.
CABLE: 6 feet of PVC-jacketed cable standard; 2-conductor for
emitters, 5-conductor for all other models. Quick-disconnect (QD)
models are available optionally. Model MBCC-512 5-conductor
cable for "QD" models must be purchased separately. Emitters use
3-conductor model MBCC-312 cable (purchase separately). See
pages 18 and 19 for "QD" cable information.
Functional Schematic
* SMA units: 90-130V ac
SMB units: 210-250V ac
SMW units: 12-28V ac or dc
For emitter hookup, see page 8.
NOTE: relay contacts are rated at 5 amps
maximum (resistive load). See specifications.
BROWN
BLUE
BLACK
(N.O. Contact)
YELLOW (Relay Common)
WHITE
(N.C. Contact)
SMW915 or 95 models: 12-2 8V ac/dc
SMA915 or 95 models: 90-1 30V ac
SMB915 or 95 models: 210- 250V ac
Hookup Diagram
10
VALU-BEAM 915 Series
Sensors with Electromechanical Relay Output