beautypg.com

Hookup diagrams, Bn bu − + bk wh, 30v dc – Banner D11 Series User Manual

Page 4

background image

Action

Indicator Status

Red LED: Pulses to indicate relative received signal strength

TEACH Condition #1
Present the first sensing condition to the sensor and single-click
the button.

3

This condition corresponds to the sensor output ON state.

Green: Flashes at 2 Hz
Yellow: OFF
Red: Pulses to indicate relative received signal strength.

TEACH Condition #2
Present the second sensing condition to the sensor and single-
click the button.
This condition corresponds to the sensor output OFF state.

Green, Yellow, and Red indicators flash simultaneously one to four
times to indicate relative sensing contrast (see chart above).
After a few seconds, the sensor returns to RUN mode.

Output Pulse Stretcher
A 40 millisecond pulse stretcher (OFF-delay) may be enabled for applications where a very short sensing event might be missed because
of the response of the load or input connected to the sensor output. Turn the pulse stretcher ON or OFF using the following procedure.

Action

Indicator Status

Push and hold the button for more than 2 seconds.

Green LED: Flashes at 1 Hz
Amber LED: Off
Red LED: Pulses to indicate relative received signal strength

Pulse Stretcher
Double-click the button to display status.
Single-click the button to toggle pulse stretcher ON or OFF

Pulse Stretcher ON

Green: Off
Amber: Off
Red: Solid on

Pulse Stretcher OFF

Green: Off
Amber: Off
Red: Double-flash

Double-click the button to save the configuration and return to Run
mode.

See

Run Mode

on page 2

Hookup Diagrams

Sensors with NPN (Sinking) Outputs

Sensors with PNP (Sourcing) Outputs

bn
bu

+

bk
wh

Load

10-30V dc

Load

Remote programming

switch (normally open)

Figure 1. Cabled Hookup

bn
bu

+

bk
wh

Load

10-30V dc

Load

Remote programming

switch (normally open)

Figure 2. Cabled Hookup

3

The sensor returns to RUN mode if the first TEACH condition is not registered within 20 seconds. TEACH mode may be cancelled before either condition #1 or #2 by pressing the push
button for more than 2 seconds.