Analog Q45UR Series Specifications
Indicators
Performance Specifications
* Resolution and linearity are
specified using a 50 mm x
50 mm (2" x 2") aluminum
plate at 22ºC under fixed
sensing conditions using the
4-20 mA output @15V dc.
Range for Nominal Sensing
Position
Near Limit: 50 mm (2") min.
Far Limit: 250 mm (10") max.
Supply Protection Circuitry
Protected against reverse polarity and transient voltages
Output Configuration
One voltage sourcing and one current sourcing; one or the other output is enabled by internal
programming switch #2 (see page 2).
Output Rating
Voltage Sourcing: 0 to 10V dc, 10mA maximum
Current Sourcing: 4 to 20mA, 1 to 500 ohm impedance
Output Protection Circuitry
Both outputs are protected against continuous overload and short circuit
Supply Voltage and Current
15 to 24V dc (10% maximum ripple) at 100 mA, exclusive of load
Adjustments
Push-button TEACH-mode programming of window limits (see page 2)
The following may be selected by a 4-position DIP switch located on top of the controller, beneath the
transparent acrylic and black inner covers (see page 2)
Switch 1: Output slope: output value increases or decreases with distance
Switch 2: Output mode: current output or voltage output
Switches 3&4: Response to loss of echo: (see page 3)
Response Speed Adjustment: Single-turn potentiometer selects six response values from 10 to 320
milliseconds (see page 3)
Resolution*:
0.2% of sensing distance at 320 ms response
0.4% of sensing distance at 10 ms response
Linearity*:
±1.0 mm (0.04") with 100 to 200 mm sensing window
±2.0 mm (0.08") with 50 to 250 mm sensing window
Temperature stability: ±0.03% of sensing distance per ºC from 0 to 50ºC (±0.05% per ºC over remainder
of operating temperature)
Ultrasonic beam angle: ±3.5º
Also see response curve on page 5
Minimum target size is specified as a 10 x 10 mm (0.4" x 0.4") aluminum plate (at any point within the 50 to
150 mm sensing range).
Construction
Controller: Molded thermoplastic polyester housing, o-ring sealed transparent acrylic top cover, and
stainless steel hardware
Sensors:
M18C2.0: Stainless steel M18 threaded barrel housing and jam nuts, ULTEM
®
polyetherimide
front cover, ceramic transducer, TEXIN
®
polyurethane rear cover
S18C2.0: Thermoplastic polyester S18 threaded barrel housing and jam nuts, ULTEM
®
polyetherimide front cover, ceramic transducer, TEXIN
®
polyurethane rear cover
Q13C2.0: Molded 30% glass reinforced thermoplastic polyester housing, ceramic transducer,
fully epoxy-encapsulated
Environmental Rating
Controller:
IEC IP67; NEMA 6P
Sensor:
IEC IP65; NEMA 4
Three status LEDs:
Green ON steady
= Power to controller is ON
Green flashing
= Current output fault detected (indicates that the 4-20 mA current path to ground
has been opened)
Yellow ON steady
= Target is sensed within the window limits (Yellow LED also indicates
programming status during setup mode)
Red flashing
= Relative strength of received echo
5-segment moving dot LED indicates the position of the target within the sensing window
ULTEM
®
is a registered trademark of General Electric
TEXIN
®
is a registered trademark of Bayer Corporation