Programming the Sensing Window Limits
The Q45UR controller features a single push button for
programming the sensing window limits (Figure 1). The
window limits may be set in one of two ways:
programming two independent window limits, or defining a
sensing distance set point, which will be centered
automatically within a 5-mm window (specific steps are
described on page 5).
Independent Window Limits: The target is placed at the
desired position to set the first limit, then the second limit
is set using the same procedure. In order to set two
independent limits, the window must at least 5 mm.
Sensing Distance Set Point: The sensor is taught the same
set point for both window limits. The set point is
automatically centered within a 5-mm (0.2") window.
See page 5 for detailed programming instructions.
Status Indicators
Status indicator LEDs are visible through the transparent,
o-ring sealed Lexan
®
top cover. Indicator function in the
RUN mode is, as follows:
•
The green LED is ON steadily whenever power is
applied to the sensor, and flashes to indicate a
current output fault.
•
The red LED lights when an echo is received, and
flashes at a rate that is proportional to echo strength.
•
The yellow LED lights whenever the target is within
the operating window limits.
The 5-segment moving dot LED indicator displays the relative
position of the target within the programmed sensing window.
The #1 LED flashes when the target is closer than the near
limit. The #5 LED flashes when the target is beyond the far limit.
1
ON
2
3
4
See Table Below for
Programming Information
Limits
N
1 2 3 4 5
Green Power
Indicator
Red Signal
Indicator
Yellow Output
Indicator
Response
Speed Selector
(10 to 320 ms)
Sensing
Window Limits
Programming
Push Button
5-Segment Target
Position Indicator
(N = Near)
Slots for Inner
Cover Removal
Figure 1. Analog Q45UR controller features
Figure 2. Analog Q45UR controller programming DIP switches
(factory default settings)
D