Bryant 588A User Manual
Page 4

ARI* COOLING CAPACITIES
UNIT 588A
NOMINAL
STANDARD
NET COOLING†
SEER†**
SOUND RATINGS††
TONS
CFM
CAPACITIES (Btuh)
(Bels)
018
1
1
⁄
2
600
17,000
10.0
7.4
024
2
800
24,000
10.0
7.6
030
2
1
⁄
2
1000
29,200
10.0
8.0
036
3
1200
36,000
10.0
8.0
042
3
1
⁄
2
1400
42,500
10.0
8.2
048
4
1600
47,000
10.0
8.2
060
5
1995
59,500
10.0
8.2
LEGEND
Bels
— Sound Levels (1 bel = 10 decibels)
db
— dry bulb
SEER — Seasonal Energy Efficiency Ratio
wb
— wet bulb
*ARI — Air-conditioning and Refrigeration Institute.
†Rated in accordance with U.S. Government DOE (Department of
Energy) test procedures and/or ARI Standard 210/240.
**All units have factory-installed time-delay relay.
††Rated in accordance with ARI Standard 270.
NOTE: Capacity ratings are net values, reflecting the effects of circulat-
ing fan heat. Ratings are based on 80 F db, 67 F wb indoor entering-air
temperature and 95 F db air entering outdoor unit.
OUTDOOR SOUND: ONE-THIRD OCTAVE BAND DATA — DECIBELS
FREQUENCY (Hz)
UNIT 588A
018
024
030
036
042
048
060
63
49.8
38.1
45.7
47.8
45.5
56.0
54.3
125
56.5
55.0
58.1
59.3
61.2
65.6
65.1
250
60.3
65.3
68.7
67.4
70.4
71.5
71.5
500
59.8
67.2
64.7
68.8
69.9
71.4
72.7
1000
64.1
68.9
73.0
73.1
76.5
74.2
73.9
2000
64.1
65.5
70.2
69.5
71.3
73.3
73.4
4000
65.2
63.8
68.8
68.2
73.7
69.6
71.7
8000
56.0
60.3
66.6
65.8
65.5
67.1
66.3
HEATING CAPACITIES AND EFFICIENCIES
UNIT 588A
HEATING INPUT
(Btuh)
OUTPUT CAPACITY
(Btuh)
TEMPERATURE
RISE RANGE (°F)
AFUE (%)
CSE (%)
018040
024040
030040
40,000
32,800
20-50
20-50
20-50
81.0
81.0
81.0
76.5
76.5
76.5
024060
030060
036060
042060
60,000
48,600
25-55
25-55
25-55
25-55
81.0
81.0
81.0
81.0
77.5
77.5
77.5
77.5
030080
036080
042080
048080
060080
80,000
64,800
40-70
40-70
40-70
40-70
40-70
81.0
81.0
81.0
81.0
81.0
77.5
77.5
77.5
77.5
77.5
036100
042100
048100
060100
100,000
81,000
50-80
50-80
50-80
50-80
81.0
81.0
81.0
81.0
78.0
78.0
78.0
78.0
036120
042120
048120
060120
120,000
97,200
60-90
60-90
60-90
60-90
80.0
80.0
80.0
80.0
77.5
77.5
77.5
77.5
048140
060140
140,000
113,000
50-80
50-80
80.0
80.0
77.5
77.5
LEGEND
AFUE — Annual Fuel Utilization Efficiency
CSE
— California Seasonal Efficiency
NOTE: Before purchasing this appliance, read important energy cost
and efficiency information available from your retailer.
4