Specifications – Bryant 588A User Manual
Page 11

SPECIFICATIONS
UNIT SIZE 588A
018040
024040
024060
030040
030060
030080
NOMINAL CAPACITY (tons)
1
1
⁄
2
2
2
2
1
⁄
2
2
1
⁄
2
2
1
⁄
2
OPERATING WEIGHT (lb)
Without Base Rail
272
303
315
320
324
324
With Optional Base Rail
296
327
339
344
356
356
COMPRESSOR
Type
Rotary
Reciprocating
Quantity
1
1
REFRIGERANT
R-22
Charge (lb)
2.60
2.75
2.75
3.40
3.40
3.40
REFRIGERANT METERING DEVICE
Fixed Orifice Metering Device
CONDENSER COIL
Face Area (sq ft)
5.95
5.95
5.95
5.95
5.95
5.95
Rows...Fins/in.
1...17
1...17
1...17
2...17
2...17
2...17
CONDENSER FAN
Nominal Airflow (cfm)
1700
1700
1700
1900
1900
1900
Nominal Speed (rpm)
850
850
850
1050
1050
1050
Quantity...Diameter (in.)
1...18
1...18
1...18
1...18
1...18
1...18
Motor Hp
1
⁄
8
1
⁄
8
1
⁄
8
1
⁄
4
1
⁄
4
1
⁄
4
EVAPORATOR COIL
Face Area (sq ft)
1.83
2.29
2.29
2.29
2.29
2.29
Rows...Fins/in.
3...15
3...15
3...15
3...15
3...15
3...15
EVAPORATOR FAN
Nominal Airflow (cfm)
600
800
800
1000
1000
1000
Nominal Speed (rpm)
825
1075
1075
1075
1075
1075
Diameter x Width (in.)
10 x 10
10 x 10
10 x 10
10 x 10
10 x 10
10 x 10
Motor Hp (single-phase)
1
⁄
4
1
⁄
4
1
⁄
4
1
⁄
4
1
⁄
4
1
⁄
4
(three-phase)
—
—
—
1
⁄
4
1
⁄
4
1
⁄
4
FURNACE SECTION*
Burner Orifice No. (Qty...drill size)
Natural Gas
1...32
1...32
2...40
1...32
2...40
2...32
Burner Orifice No. (Qty...drill size)
Propane Gas
1...41
1...41
2...47
1...41
2...47
2...42
RETURN-AIR FILTERS (in.)†
Throwaway
20 x 20
20 x 20
20 x 20
20 x 24
20 x 24
20 x 24
UNIT SIZE 588A
036060
036080
036100
036120
042060
042080
NOMINAL CAPACITY (tons)
3
3
3
3
3
1
⁄
2
3
1
⁄
2
OPERATING WEIGHT (lb)
Without Base Rail
336
336
348
348
375
375
With Optional Base Rail
360
360
372
372
399
399
COMPRESSOR
Type
Reciprocating
Quantity
1
REFRIGERANT
R-22
Charge (lb-oz)
4.30
4.30
4.30
4.30
5.20
5.20
REFRIGERANT METERING DEVICE
Fixed Orifice Metering Device
CONDENSER COIL
Face Area (sq ft)
5.95
5.95
5.95
5.95
7.04
7.04
Rows...Fins/in.
2...17
2...17
2...17
2...17
2...17
2...17
CONDENSER FAN
Nominal Airflow (cfm)
1900
1900
1900
1900
1900
1900
Nominal Speed (rpm)
1050
1050
1050
1050
1050
1050
Quantity...Diameter (in.)
1...18
1...18
1...18
1...18
1...18
1...18
Motor Hp
1
⁄
4
1
⁄
4
1
⁄
4
1
⁄
4
1
⁄
4
1
⁄
4
EVAPORATOR COIL
Face Area (sq ft)
3.06
3.06
3.06
3.06
3.33
3.33
Rows...Fins/in.
3...15
3...15
3...15
3...15
3...15
3...15
EVAPORATOR FAN
Nominal Airflow (cfm)
1200
1200
1200
1200
1400
1400
Nominal Speed (rpm)
1100
1100
1100
1100
1100
1100
Diameter x Width (in.)
10 x 10
10 x 10
10 x 10
10 x 10
10 x 10
10 x 10
Motor Hp (single-phase)
1
⁄
2
1
⁄
2
1
⁄
2
1
⁄
2
3
⁄
4
3
⁄
4
(three-phase)
1
⁄
2
1
⁄
2
1
⁄
2
1
⁄
2
3
⁄
4
3
⁄
4
FURNACE SECTION*
Burner Orifice No. (Qty...drill size)
Natural Gas
2...40
2...32
2...30
3...32
2...40
2...32
Burner Orifice No. (Qty...drill size)
Propane Gas
2...47
2...42
2...40
3...42
2...47
2...42
RETURN-AIR FILTERS (in.)†
Throwaway
20 x 24
20 x 24
20 x 24
20 x 24
24 x 24
24 x 24
*Based on an altitude of 0-2000 ft.
†Required field-supplied filter sizes are based on the larger of the ARI-rated (Air Conditioning & Refrigeration Institute) cooling airflow or the heating
airflow at a velocity of 300 ft/min for throwaway type. Air filter pressure drop for non-standard filters must not exceed 0.08 in. wg.
**Sq inch. Filter is mounted external to unit.
11